12.07.2015 Views

Pneumatic Clean Series

Pneumatic Clean Series

Pneumatic Clean Series

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Solenoid Valve 10-SY100365ModelActuationValveOperating Vacuum specifications MPaStyle pressure rangeMPaP port R portEffective areamm 2Note 2) Weight gGrommettypeL/Mplug connectorN.C. 10-SY1134Standard0 to 0.7–100kPa to 0.6–100kPa to 00.143N.C. 10-SY11 ANote 1)N.O. 10-SY12434HighflowStandard0 to 0.70 to 0.7–100kPa to 0.6–100kPa to 0–100kPa to 0 –100kPa to 0.60.220.14SY13(A): 13 SY13(A): 15SY14(A): 24 SY14(A): 26Withoutsub-plate12Note 1)3 HighN.O. 10-SY12 4Aflow0 to 0.7 –100kPa to 0 –100kPa to 0.6 0.22Note 1) In case of 10-SY12 3 or 10-SY12344A, apply pressure from R port and exhaust air from P port.Note 2) Values are for DC. Add 1 g in case of AC.Withoutsub-plate14JIS symbol3SY11 4(A)AP R3SY12 4(A)AP RSpecificationsFluidAmbient and fluid temperature °CNote1) Response time msMax. operating frequency HzManual overrideAirMax. 5010 or less20Non-locking push type, Slotted locking typePush-turn locking slotted typePush-turn locking lever typeLubricationNot requiredMounting orientationFreeNote2) Impact/Vibration resistance m/s 2150/30EnclosureDust proofNote 1) According to JISB8374-1981 dynamic performance test (With coil temperature of 20°C, at ratedvoltage and without surge voltage suppressor)Note 2) Impact resistance:No malfunction resulted in an impact test using a drop impact tester. The test wasperformed each time in the axial and right angle directions of the main valve andarmature, for both energized and deenergized states (value in the initial stage).Vibration resistance: No malfunction resulted from a one-sweep test between 8.3 and 2000Hz.The test was performed on the axis and right angle directions of the main valveand armature, for both energized and de-energized states.(Value in the initial stage).Solenoid Specifications<strong>Series</strong>Electrical entryRated coil voltage VAllowable voltage fluctuationNote) Power consumption WNote) Apparent power VADC50/60Hz ACACDC100V110V[115V]200V220V[230V]Surge voltage suppressorIndicator light∗110VAC and 115VAC are common, as are 220VAC and 230VAC.Note) At rated voltage10-SY1 13 24 10-SY1 13 24AGrommet (G)/(H), L plug connector (L),M plug connector (M)24, 12, 6, 5, 3100, 110, 200, 220 —–10 to +10%0.5 (With light: 0.55) 0.75 (With light: 0.8)0.9 (With light: 1.0)1.0 (With light: 1.1)[1.1 (With light: 1.2)]—1.8 (With light: 1.9)1.9 (With light: 2.0)[2.2 (With light: 2.3)]DiodeLED346

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!