Solenoid Valve 10-VQ1000/2000420ModelFlow characteristics Note 1)Note 2)<strong>Series</strong> Number of solenoids Model 14/2 (PA/B) 4/25/3 (A/BR1/R2) Response time WeightmsgC[dm 3 /(s·bar)] b Cv C[dm 3 /(s·bar)] b Cv10-VQ100010-VQ20002 position2 positionSingleSpecificationsDouble(Latching)SingleDouble(Latching)Metal seal 10-VQ1140YRubber seal 10-VQ1141YMetal seal 10-VQ1240Rubber seal 10-VQ1241Metal seal 10-VQ2140YRubber seal 10-VQ2141YMetal seal 10-VQ2240Rubber seal 10-VQ224115 or less20 or less15 or less20 or less29 or less31 or less29 or less31 or lessNote 1) Cylinder ports: C6 (10-VQ1000) and C8 (10-VQ2000)Note 2) According to JIS B8375-1981. (A value at supply pressure of 0.5MPa{5.1kgf/cm2} with light/surge voltage suppressor when clean air is used.The value differs with the pressure and the quality of air.)0.770.910.770.912.02.32.02.30.140.190.140.190.130.210.130.210.180.210.180.210.430.540.430.540.841.00.841.02.32.72.32.70.140.210.140.210.150.250.150.250.190.250.190.250.580.620.580.6257103ValvespecificationsValve typeMetal sealRubber sealFluidAir, Inert gasMax. operating pressure0.7MPa0.7MPaSingle0.1MPa0.15MPaMin. operating pressure Double (Latching)0.18MPa0.18MPa3 positions 0.15MPa 0.2MPaAmbient and fluid temperatureLubricationManual overrideEnclosureRated coil voltageAllowable voltage fluctuationElectricspecificationsType of coil insulationPower consumption DC 24VDC(Current)12VDCNote 1) Use dry air to prevent condensation when operating at a low temperature.–10 to 50°C Note 1) –10 to 50°C Note 1)Not requiredPush type/Option: Locking type (tool required, lever)Dust proof12V, 24VDC±10% of rated voltageEquivalent to class B0.5W DC (21mA)0.5W DC (42mA)DirectionalControl ValvePrecautions to Install Threaded Fitting AssemblyThreaded fitting assemblys used for this manifold are not mounted on themanifold base or valve in order to improve installation efficiency ofconnecting the fittings to the port.Precautions to install threaded fitting assembly.1. Screw in the fitting to the ancillary threaded fitting assembly.The fitting to be usedO-ringPrecautions1. Be careful not to scratch or stain the O-ring of the fitting assembly.It may cause air leakage. To prevent exhaust air at EXH from pressurization (0.3 MPa or more)by throttling, double side piping is recommended for EXH port.(Otherwise delay in response or air leakage may result.)Threaded fitting assembly2. Insert the threaded fitting assembly into the manifold port.Valve3. Insert the ancillary clip into the groove on the bottom surface ofthe valve.401

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!