<strong>Series</strong> SRH664OptionsPressure GaugeProcedure for setting the limit gauge indicatorDimensions46.526.514121) Before setting the limit indicator, turn the cover counterclockwise(approximately 6 to 7 mm) until it stops. Then, remove by pulling ittowards you.CoverTurn counterclockwiseuntil the cover stops.ø42PullSpecificationsR1/4ItemModel G46--02-SRA G46--02-SRBPort sizeOperating temperaturerangeAccuracyScale rangeR1/40 to 60°C (With no condensation)±3%F.S.270°Parts washing(fluid-contact parts)Assembly & adjustmentenvironmentPrecision wash<strong>Clean</strong> roomGeneral degreaseGeneral production lineOil free / Water freeFluid-contact partsNon-lube / Non-wetStainless steel SUS316MaterialsCaseStainless steel SUS304 (Black melamine coating)Clear cover Polycarbonateca (Hard coated) Part No. G46-00-00-2Internal partsBrassWeight80g2) Use a flat head screwdriver (with a 2.9 mm blade width) to set thelimit indicator.Be careful not to bend other needle or damage the dial plate.Limit indicatorFlat head screw driver3) After completing the setting, replace the cover.Fit the cover by aligning the cutout in the cover to the groove onthe top of the black case. Turn the cover clockwise (approximately6 to 7 mm) and make sure that the matching mark on the cover isaligned with the groove on the top of the case.MarkHollowSlitModelsModelG46-2-02-SRAPressure rangeMPa0 to 0.2Indicator unitsG46-2-02-SRBG46-4-02-SRA0 to 0.4G46-4-02-SRBMPaG46-7-02-SRA0 to 0.7G46-7-02-SRBG46-10-02-SRA0 to 1.0G46-10-02-SRBNote) Consult SMC for the supply of types with metal gasket seal.Specific Product PrecautionsBe sure to read before handling.Refer to page 8 for Safety Instructions.CautionSelection1) Avoid use in locations with strong pressure pulsation or vibration.2) Contact SMC if the product is to be used in an application with ahigh frequency of operation.CautionMounting1) Do not subject the gauge to shocks, such as dropping duringtransportation and mounting, as this can cause loss of indicationaccuracy.2) Do not use this gauge in a location with high temperature andhumidity, as this may cause faulty operation.3) When mounting the pressure gauge, be certain to use a wrench onthe square wrench flats to screw it into place. If the wrench isapplied on any other part, air leakage or other damage may occur.6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!