Mini Free Mount Cylinder 10-CUJ/11-CUJ69Specific Product PrecautionsBe sure to read before handling.Refer to pages 7 to 16 of Front matter for safety instructions and common precautions for clean series andpages 2 to 7 for common precautions for actuators.CautionMountingWhen mounting a mini free mount cylinder, tighten thebolts with the proper tightening torque.ø6ø8ø10BoltM3 X 0.5Appropriate tightening torque Nm1.06With Auto SwitchSelectionStrictly observe the limiting range of lateral load on a pistonrod. (See the graphs below.) If this product is used beyondthe limits, it may shorten the machine life or cause damage.0.5ø10Without Auto Switch0.40.4ø10Tightening torqueTightening torqueAllowable lateral load W (N)0.30.2ø8ø6Allowable lateral load W (N)0.30.2ø8ø60.10.1CautionAllowable Kinetic EnergyWhen driving an inertial load, operate a cylinder with kineticenergy not exceeding the allowable value. The range in thechart below delineated by bold solid lines indicates therelation between load weights and maximum driving speeds.Bore size (mm)Piston speed (m/s)Allowable kinetic energy (J)68106.25 X 10 -3 9.35 X 10 -3 12.5 X 10 -30.05 to 0.40 4 6 8 10 15 20Stroke (mm)0 4 6 8 10 15 20Stroke (mm)10Load weight kg10.1ø10ø8ø60.010.01 0.1 0.4 1.0Maximum speed V (m/s)50