12.07.2015 Views

Pneumatic Clean Series

Pneumatic Clean Series

Pneumatic Clean Series

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Solenoid Valve 10-VQ1000/2000410Model<strong>Series</strong> Number of solenoids Model10-VQ10002 positionSingleDouble(Latching)Metal seal 10-VQ1130YRubber seal 10-VQ1131YMetal seal 10-VQ1230Rubber seal 10-VQ123114/2 (PA/B)C[dm 3 /(s·bar)] b Cv0.770.910.770.910.140.190.140.19Note 1)Flow characteristics0.180.210.180.214/25/3 (A/BR1/R2)C[dm 3 /(s·bar)] b Cv0.841.00.841.00.140.210.140.210.190.250.190.25Note 2)Response timems15 or less20 or less15 or less20 or lessNote 1) Cylinder port size C6.Note 2) According to JIS B8375-1981 (At supply pressure of 0.5MPa with light/surge voltage suppressor. The value differs with the pressure and the quality of air.)Weightg57SpecificationsValvespecificationsValve typeFluidNote 3) Max. operating pressureMin.operating pressureAmbient and fluid temperatureLubricationManual overrideEnclosureRated coil voltageAllowable voltage fluctuationElectricalspecificationsType of coil insulationPower consumption DC 24VDC(Current)12VDCNote 1) Use dry air to prevent condensation when operating at a low temperature.Precautions to Install Threaded Fitting AssemblyThreaded fitting assemblis used for this manifold are not mounted on themanifold base or valve in order to improve installation efficiency ofconnecting the fittings to the port.Install the threaded fitting following the steps below.1. Screw in the fitting to the ancillary threaded fitting assembly.The fitting to be usedO ringMetal seal0.7MPaAir, Inert gasRubber seal0.7MPaSingle0.1MPa0.15MPaDouble (Latching)0.18MPa0.18MPa3 position 0.1MPa 0.2MPa–10 to 50°C Note 1) –10 to 50°C Note 1)Not requiredPush type/Option: Locking type (tool required, lever)Dust proof12V, 24VDC±10% of rated voltageEquivalent to class B0.5W DC (21mA)0.5W DC (42mA)Precautions1. Be careful not to scratch or stain the O-ring of the fitting assembly.It may cause air leakage. To prevent exhaust air at EXH from pressurization (0.3 MPa or more)by throttling, double side piping is recommended for EXH port.(Otherwise delay in response or air leakage may result.)DirectionalControl ValveThreaded fitting ass'y2. Insert the threaded fitting assembly into the manifold port.Valve3. Insert the ancillary clip into the groove on the bottom surface ofthe valve.391

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!