Modify Audit Log Settings in Windows Server 2008<br />

Initial District Setup<br />

If GradeBook is running on Windows Server 2008, modify PBAudit log settings, as desired.<br />

1. In the Event Viewer, expand the Applications and Services Logs node.<br />

2. Right-click on PBAudit, and select Properties.<br />

3. On the Log Properties - PBAudit window, if you want to store the log file on a different drive<br />

than the default location, C:\Program Files (x86)\Software Answers\Event Log, then type<br />

the location in the Log path field.<br />

4. In the Maximum log size (KB) list, select a value that represents the maximum size the file<br />

can be.<br />

The default value is 1,028.<br />

5. In the When maximum event log size is reached section, select one of the following<br />

options:<br />

• Overwrite events as needed (oldest events firsts)<br />

• Archive the log when full, do not overwrite events – This is the recommended<br />

option. When the log file reaches the maximum file size limit, it stops writing records<br />

in that file and creates a new log file.<br />

• Do not overwrite events (Clear logs manually)<br />

Note: You may select different maximum event log size options at different sites,<br />

as needed.<br />

Windows Server 2008 LogProperties – PBAudit<br />

Window<br />

6. Click Apply, and then OK.<br />

The Log Properties - PBAudit window closes.<br />

7. Close the Event Viewer.<br />