n051<br />
Selection of Running After Restoration Following a<br />
Momentary Stop<br />
Setting range 0, 1, and 2 Unit --- Default setting<br />
0<br />
• Select with n051 a method to process instantaneous power failure.<br />
Set Values<br />
Set<br />
Description<br />
value<br />
0 Inverter will discontinue running.<br />
1 Inverter will continue running if power is supplied again within instantaneous power<br />
failure compensation time set with n055. (see note 1)<br />
2 Inverter will always continue running without detecting UV1 or UV3. (see notes 1 and 2)<br />
Note 1. Keep the run command ON to permit the Inverter to restart operation automatically<br />
when power is supplied to the Inverter after the operation of the Inverter is interrupted<br />
due to an instantaneous power failure.<br />
Note 2. If n051 is set to 2, the Inverter will restart running after supply voltage to the Inverter<br />
returns to normal and the Inverter will not detect error output signals.<br />
n052<br />
Speed Search Control Level<br />
Setting range 0 to 200 Unit % (Rated output<br />
current ratio)<br />
Default setting<br />
150<br />
• Set with n052 a current level in 1% units based on the rated output current<br />
as 100% which enables the Inverter to determine the completion<br />
of the speed search control.<br />
• It is usually not necessary to change the default-set value.<br />
• To permit the Inverter to use the speed search function, set the multifunction<br />
input parameter used by the Inverter to 15 or 16 so that the<br />
speed search command will be input to the Inverter.<br />
• When the output current becomes less than the value set with n054,<br />
the Inverter in speed search control will detect the synchronous speed<br />
and the Inverter will be in acceleration mode.