Data<br />

display<br />

%h3<br />

flashing<br />

%l3<br />

flashing<br />

bb<br />

flashing<br />

call<br />

flashing<br />

%pe3<br />

%pe5<br />

%pe6<br />

Description<br />

Inverter overheat warning<br />

(OH3)<br />

Inverter overheat warning as<br />

multi-function input was<br />

received by the Inverter.<br />

Overtorque (OL3)<br />

A current exceeding the value<br />

set with n075 flowed for more<br />

than the time set with n076.<br />

Remote baseblock (bb)<br />

The remote baseblock<br />

command input as<br />

multi-function input was<br />

received by the Inverter.<br />

Operation mode error<br />

(CALL)<br />

The setting of n002 was<br />

improper.<br />

Multi-function input setting<br />

error<br />

The multi-function input<br />

settings of n035 to n039 were<br />

improper.<br />

V/f data setting error<br />

Optional V/f pattern settings<br />

were improper.<br />

Parameter setting error<br />

Parameter settings other than<br />

the ones used for<br />

multi-function input and V/f<br />

pattern settings were<br />

improper.<br />

Cause and action<br />

→ Turn OFF inverter overheat warning.<br />

→ Check whether the n075 and n076 settings are<br />

appropriate.<br />

→ Check the machine use status and eliminate the<br />

cause of the problem.<br />

→ Turn OFF the remote baseblock command input.<br />

The parameter n002 was set to a value other than 0 to 3.<br />

→ Reset n002.<br />

Make sure that the values of n035 to n039 are different<br />

from one another.<br />

Make sure that a single search mode is selected with<br />

n035 to n039 set to 15 or 16.<br />

Make sure that both set values 22 and 25 are selected<br />

with n035 to n039.<br />

Reset the optional V/f pattern to satisfy the following<br />

condition.<br />

→ n017 n015 n014 n012<br />

Check whether the rated input current of the motor set<br />

with n032 satisfies the following condition. If not, check<br />

the rated current of the motor and reset n032.<br />

→ Rated input current of Inverter x 0.1 n032 rated<br />

input current of Inverter x 2<br />

Jumping frequency 1 set with n058 is higher than jumping<br />

frequency 2 set with n059. Reset jumping frequencies 1<br />

and 2 to satisfy the following condition.<br />

→ n058 n059<br />

The upper limit of the output frequency set with n030 is<br />

lower than the lower limit of the output frequency set with<br />

n031. Reset the upper and lower limits of the output<br />

frequency to satisfy the following condition.<br />

→ n030 n031