Optional<br />

frequency<br />

detection<br />

Overtorque<br />

detection<br />

Timer function<br />

n071<br />

n072<br />

n073<br />

n074<br />

n075<br />

n076<br />

n077<br />

n078<br />

Function No. Name Description Setting<br />

range<br />

Stall prevention<br />

n070<br />

0, 1<br />

Decelerating<br />

stall<br />

prevention<br />

selection<br />

Accelerating<br />

stall<br />

prevention<br />

operation<br />

level<br />

Operating<br />

stall prevention<br />

operation<br />

level<br />

Frequency<br />

detection<br />

level<br />

Overtorque<br />

detection<br />

function<br />

selection<br />

Overtorque<br />

detection<br />

level<br />

Overtorque<br />

detection<br />

time<br />

Timer function<br />

ON<br />

delay time<br />

Timer function<br />

OFF<br />

delay time<br />

0: Inhibits deceleration stall prevention<br />

from functioning.<br />

1: Permits deceleration stall prevention to<br />

function.<br />

Set current level enabling acceleration stall<br />

prevention in 1% units based on rated output<br />

current of Inverter as 100%.<br />

Set current level enabling operation stall<br />

prevention in 1% units based on rated output<br />

current of Inverter as 100%.<br />

Set detecting output frequency in 1-Hz<br />

units.<br />

Valid if multi-function contact output is set<br />

to optional frequency agreement or optional<br />

frequency detection.<br />

0: Inhibits Inverter from detecting overtorque.<br />

1: Inverter will detect overtorque only during<br />

speed agreement and continue running<br />

with warning after detection.<br />

2: Running Inverter will detect overtorque<br />

and continue running with warning after<br />

detection.<br />

3: Inverter will detect overtorque only during<br />

speed agreement and turn OFF<br />

output for safety when overtorque is<br />

detected.<br />

4: Running Inverter will always detect<br />

overtorque and turn OFF output for<br />

safety when overtorque is detected.<br />

Set overtorque detection current in 1%<br />

units based on rated output current of Inverter<br />

as 100%.<br />

Set overtorque detection time in 1-s units.<br />

Overtorque will be detected if current larger<br />

than value set with n075 flows for the<br />

set time or more.<br />

Set time lag between moment timer function<br />

input turns ON and moment timer<br />

function output turns ON.<br />

Valid if multi-function input and multi-function<br />

contact output are set to timer function.<br />

Set time lag between the moment the timer<br />

function input turns OFF and the<br />

moment the timer function output turns<br />

OFF.<br />

Valid if multi-function input and multi-function<br />

contact output are set to timer function.<br />

[1]<br />

30 to<br />

200<br />

[170]<br />

30 to<br />

200<br />

[160]<br />

0.0 to<br />

400.0<br />

[0.0]<br />

0 to 4<br />

[0]<br />

30 to<br />

200<br />

[160]<br />

0.1 to<br />

10.0<br />

[0.1]<br />

0.0 to<br />

25.5<br />

[0.0]<br />

0.0 to<br />

25.5<br />

[0.0]<br />

User<br />

setting