Function<br />

Frequency<br />

reference<br />

function<br />

selection<br />

No.<br />

n040<br />

n041<br />

n042<br />

n043<br />

n044<br />

n045<br />

n046<br />

Name<br />

Sequential<br />

output function<br />

selection<br />

Multi-function<br />

contact<br />

output 1<br />

(MA-MB-<br />

MC)<br />

Multi-function<br />

contact<br />

output 2<br />

(M1-M2)<br />

Analog frequency<br />

reference<br />

voltage/current<br />

selection<br />

FI input level<br />

selection<br />

Analog frequency<br />

reference<br />

sample<br />

hold selection<br />

Processing<br />

selection<br />

when analog<br />

frequency<br />

reference<br />

is<br />

lost<br />

Frequency<br />

reference<br />

gain<br />

Description<br />

0: Error (ON: Error)<br />

1: Running<br />

2: Frequency agreement<br />

3: Optional frequency agreement<br />

4: Optional frequency detection (ON:<br />

Output frequency n073)<br />

5: Optional frequency detection (ON:<br />

Output frequency n073)<br />

6: Overtorque (ON: Detected)<br />

7: Overtorque (OFF: Detected)<br />

8: Baseblock<br />

9: Operation mode (ON: Digital Operator/Frequency<br />

reference)<br />

10: Inverter ready<br />

11: Timer function output (Set with n077<br />

and n078)<br />

12: Error retrying<br />

13: Inverter/Motor overload warning<br />

14: Frequency reference loss (ON: Frequency<br />

reference has dropped by<br />

90% or more within 0.4 s)<br />

15: Not used<br />

16: PID feedback loss (Detecting method<br />

can be set with n093 and n094)<br />

17: Heating heat sink (ON: OH1)<br />

Setting<br />

range<br />

0 to 17<br />

[0]<br />

Same as n040 0 to 17<br />

0: The FV terminal can be used for the<br />

analog frequency reference within a<br />

voltage range from 0 to 10 VDC.<br />

1: The FI terminal can be used for the<br />

analog frequency reference. Set the<br />

input level with n043.<br />

0: Voltage input within a range from 0 to<br />

10 V. Be sure to cut jumper wire J1.<br />

1: Current input within a range from 4 to<br />

20 mA.<br />

0: Frequency reference on hold is not<br />

saved.<br />

1: Frequency reference on hold is saved<br />

by n025<br />

0: Inhibits Inverter from processing analog<br />

frequency reference loss.<br />

1: Permits Inverter to process analog frequency<br />

reference loss.<br />

Set analog frequency reference input gain.<br />

Set input frequency at 10 V or 20 mA with<br />

1% units based on max. frequency set<br />

with n012 as 100%.<br />

[1]<br />

0, 1<br />

[0]<br />

0, 1<br />

[1]<br />

0, 1<br />

[0]<br />

0, 1<br />

[0]<br />

0 to<br />

200<br />

[100]<br />

User<br />

setting