Set Values<br />

Set value Run command Frequency reference<br />

0 Digital Operator Digital Operator<br />

1 Control circuit terminals Digital Operator<br />

2 Digital Operator Control circuit terminals<br />

3 Control circuit terminals Control circuit terminals<br />

Note Do not set n002 to any value other than the above.<br />

Frequency Reference Type Selection (n042, n046, and n047)<br />

through Control Circuit Terminal<br />

Select the FV terminal to input the frequency reference within a voltage range from 0 to 10<br />

VDC or the FI terminal to input the frequency reference within a current range from 4 to 20<br />

mA with n042.<br />

n042<br />

Analog Frequency Reference Voltage/Current Selection<br />

Setting range 0, 1 Unit --- Default setting<br />

Set Values<br />

Set<br />

Description<br />

value<br />

0 The FV terminal can be used for the analog frequency reference within a voltage range<br />

from 0 to 10 VDC.<br />

1 The FI terminal can be used for the analog frequency reference. Set the input level with<br />

n043.<br />

0<br />

Note<br />

Note<br />

1. The FI terminal is a current input terminal for 4 to 20 mA. The FI terminal can be a<br />

voltage input terminal by changing the FI input level with n043 and cutting jumper wire<br />

of the PCB. Do not, however, change the FI terminal to a voltage input terminal unless<br />

the Inverter is used for PID control.<br />

2. Set n042 according to the type of frequency reference.<br />

Set the frequency reference gain with n046 and the frequency reference bias with n047.<br />

n046<br />

Frequency Reference Gain<br />

Setting range 0 to 200 Unit % Default setting<br />

100<br />

n047<br />

Frequency Reference Bias<br />

Setting range –100 to 100 Unit % Default setting<br />

0<br />

Set Values<br />

n046: The frequency for 10-V or 20-mA input can be set in 1% units based on the maximum<br />

frequency set with n012 as 100%.