OMRON Sysdrive 3G3HV - Detector Cooling Section
OMRON Sysdrive 3G3HV - Detector Cooling Section
OMRON Sysdrive 3G3HV - Detector Cooling Section
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
n039<br />
Multi-function Input 5 (S6)<br />
Setting range 2 to 25 Unit --- Default setting<br />
Set Values<br />
Set<br />
Description<br />
value<br />
0 Reverse rotation/Stop (2-wire sequence)<br />
1 Stop command (3-wire sequence). S3 will be used for the forward/reverse rotation<br />
command and the value set with n036 will be ignored.<br />
9 Multi-step speed command 1<br />
10 Multi-step speed command 2<br />
11 Inching command<br />
12 Acceleration/Deceleration time switching command<br />
Example of Wiring for 2-wire Sequential Operation (Set Value: 0)<br />
10<br />
Forward rotation/Stop<br />
Reverse rotation/Stop<br />
Example of Wiring for 3-wire Sequential Operation (Set Value: 1)<br />
Stop switch<br />
(NC)<br />
Operation switch<br />
(NO)<br />
Run command (Operates when the<br />
operation switch is closed)<br />
Stop command (Stops when the stop<br />
switch is open)<br />
Forward/Reverse rotation command<br />
Example of Multi-step Operation (Set Values: 9 and 10)<br />
Select multi-step speed command 1 for the Inverter in two-step speed<br />
operation and multi-step speed commands 1 and 2 for the Inverter in<br />
four-step speed operation.<br />
Frequency<br />
reference<br />
Frequency<br />
reference 3<br />
Frequency<br />
reference 2<br />
Frequency<br />
reference 1<br />
Frequency<br />
reference 4<br />
Forward<br />
rotation/Stop<br />
Multi-step speed<br />
command 1<br />
Multi-step speed<br />
command 2