n039<br />

Multi-function Input 5 (S6)<br />

Setting range 2 to 25 Unit --- Default setting<br />

Set Values<br />

Set<br />

Description<br />

value<br />

0 Reverse rotation/Stop (2-wire sequence)<br />

1 Stop command (3-wire sequence). S3 will be used for the forward/reverse rotation<br />

command and the value set with n036 will be ignored.<br />

9 Multi-step speed command 1<br />

10 Multi-step speed command 2<br />

11 Inching command<br />

12 Acceleration/Deceleration time switching command<br />

Example of Wiring for 2-wire Sequential Operation (Set Value: 0)<br />

10<br />

Forward rotation/Stop<br />

Reverse rotation/Stop<br />

Example of Wiring for 3-wire Sequential Operation (Set Value: 1)<br />

Stop switch<br />

(NC)<br />

Operation switch<br />

(NO)<br />

Run command (Operates when the<br />

operation switch is closed)<br />

Stop command (Stops when the stop<br />

switch is open)<br />

Forward/Reverse rotation command<br />

Example of Multi-step Operation (Set Values: 9 and 10)<br />

Select multi-step speed command 1 for the Inverter in two-step speed<br />

operation and multi-step speed commands 1 and 2 for the Inverter in<br />

four-step speed operation.<br />

Frequency<br />

reference<br />

Frequency<br />

reference 3<br />

Frequency<br />

reference 2<br />

Frequency<br />

reference 1<br />

Frequency<br />

reference 4<br />

Forward<br />

rotation/Stop<br />

Multi-step speed<br />

command 1<br />

Multi-step speed<br />

command 2