28.01.2015 Views

OMRON Sysdrive 3G3HV - Detector Cooling Section

OMRON Sysdrive 3G3HV - Detector Cooling Section

OMRON Sysdrive 3G3HV - Detector Cooling Section

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The Inverter calculates its mean output power during the time set with n099 for the energy-saving<br />

control of the motor.<br />

The time set with n099 is used as a search operation period, in which the output voltage of<br />

the Inverter in search operation mode changes.<br />

Set n099 to a value larger than the default-set value if the load factor of the motor changes<br />

greatly or the friction factor of the load is large and the motor vibrates.<br />

n101 Search Operation Control Voltage Step when 100%<br />

Setting range 0.0 to 10.0 Unit % (Rated input<br />

voltage ratio of<br />

motor)<br />

Default setting<br />

n102 Search Operation Control Voltage Step when 5%<br />

Setting range 0.0 to 10.0 Unit % (Rated input<br />

voltage ratio of<br />

motor)<br />

Default setting<br />

Set Values<br />

The values set with n101 and n102 are used as voltage change rates, at which the output<br />

voltage of the Inverter in search operation mode changes.<br />

It is usually not necessary to change the default-set values of n101 and n102.<br />

A voltage change rate can be set according to the output voltage of the Inverter.<br />

Set n101 and n102 to values smaller than the default-set values if it is necessary to minimize<br />

the speed ripples of the motor.<br />

Auto-tuning voltage step (%)<br />

0.5<br />

0.2<br />

Inverter voltage output<br />

Effective Energy-saving Control<br />

Take the following steps to check whether the Inverter in energy-saving<br />

mode is saving unnecessary power supply to the motor.<br />

Output Power<br />

Press the ENERGY SAVE Key and POWER Key to check whether the output power of the<br />

Inverter in energy-saving mode is lower than that of the Inverter not in energy-saving mode.<br />

Motor<br />

Check that the motor does not stall or vibrate error when the Inverter performs energy-saving<br />

control.<br />

Troubleshooting of Energy-saving Control Problems<br />

If the Inverter in energy-saving mode stalls the motor, vibrates the motor, or

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!