OMRON Sysdrive 3G3HV - Detector Cooling Section
OMRON Sysdrive 3G3HV - Detector Cooling Section
OMRON Sysdrive 3G3HV - Detector Cooling Section
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
• Two acceleration times and two deceleration times can be set with the<br />
Inverter, any of which can be selected with remote output.<br />
V/f Settings<br />
• Select a V/f pattern out of the 15 V/f patterns preset with the Inverter<br />
according to the application.<br />
• An optional V/f pattern can be set with the Inverter.<br />
Monitor Function<br />
• The following items can be monitored with the Digital Operator.<br />
Frequency reference, output frequency, output current, output voltage, DC voltage, output<br />
power, status of input terminals, inverter status, power interruption error, PROM number,<br />
total operating time, and PID feedback value<br />
Low Noise (3.7- to 160-kW Models)<br />
• The output transistor of the Inverter is an IGBT (insulated gate bipolar<br />
transistor). Using a sine-wave PWM method with a high-frequency<br />
carrier, the motor does not generate metallic noise.<br />
High Torque at Low Output Frequency Range<br />
• A torque rate of 150% can be achieved even in a low speed range<br />
where output frequency is only 3 Hz.<br />
Automatic Torque Boost<br />
• The Inverter automatically adjusts the output according to the required<br />
torque of the motor that is rotating at constant or accelerative speed,<br />
thus ensuring the powerful rotation of the motor.<br />
Harmonic Countermeasures (3.7- to 160-kW Models)<br />
• DC reactors (optional) can be connected to 3.7- to 15-kW models.<br />
• Models of 18.5- to 160-kW have a built-in DC reactor and also employ<br />
12-pulse rectification, which suppresses harmonics better than a<br />
reactor.