28.01.2015 Views

OMRON Sysdrive 3G3HV - Detector Cooling Section

OMRON Sysdrive 3G3HV - Detector Cooling Section

OMRON Sysdrive 3G3HV - Detector Cooling Section

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

• Set with n071 and n072 current levels in 1% units based on the rated<br />

output current as 100% to enable the acceleration and operation stall<br />

prevention functions to work.<br />

Acceleration Stall Prevention<br />

Operation<br />

Stall<br />

Prevention<br />

Operation Stall Prevention<br />

Operation<br />

Stall<br />

Prevention<br />

Time<br />

Time<br />

Output<br />

frequency<br />

Output<br />

frequency<br />

The output frequency is controlled to a<br />

level to enable the Inverter to continue<br />

operating the motor without stalling.<br />

Time<br />

The output frequency is controlled to a<br />

level to enable the Inverter to continue<br />

operating the motor without stalling.<br />

Time<br />

n073<br />

Frequency Detection Level<br />

Setting range 0.0 to 400.0 Unit Hz Default setting<br />

• The parameter n073 is used to detect the output frequency.<br />

• The Inverter will output a signal as a multi-function contact output<br />

while the output frequency is higher than, lower than, or the same as<br />

the frequency set with n073.<br />

• Set n040 and n041 (i.e., multi-function contact output selection):<br />

To 3 to permit the Inverter to output a signal while the output frequency is the same as the<br />

frequency set with n073.<br />

To 4 to permit the Inverter to output a signal while the output frequency is the same as or<br />

lower than the frequency set with n073.<br />

To 5 to permit the Inverter to output a signal while the output frequency is the same as or<br />

higher than the frequency set with n073. Refer above.<br />

0.0<br />

n074<br />

Overtorque Detection Function Selection<br />

Setting range 0 to 4 Unit --- Default setting<br />

0<br />

n075<br />

Overtorque Detection Level<br />

Setting range 30 to 200 Unit % (Rated output<br />

current ratio)<br />

Default setting<br />

160<br />

n076<br />

Overtorque Detection Time<br />

Setting range 0.1 to 10.0 Unit s Default setting<br />

• The parameters n074, n075, and n076 are used to set the overtorque<br />

detection function.<br />

0.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!