Parameters in Detail<br />

Refer to the following for the functions of the parameters used with the Inverter<br />

not in energy-saving or PID control operation.<br />

n001<br />

Setting range 0, 1, 2, 3, 6,<br />

and 7<br />

Group 1:<br />

Group 2:<br />

Group 3:<br />

Parameter Write Prohibit Selection/Parameter<br />

Initialization<br />

Unit --- Default setting<br />

• The parameters used by the Inverter are classified into the following<br />

three groups.<br />

n001 to n034<br />

n035 to n049<br />

n050 to n108 (Up to n102 can be used.)<br />

• The Inverter is default-set so that only parameters of group 1 can be<br />

set and checked and the parameters of groups 2 and 3 can only be<br />

checked.<br />

Set Values<br />

Set<br />

Description<br />

value<br />

0 The parameters n001 can be set and checked and the parameters n002 to n108 can be<br />

only checked.<br />

1 The parameters of group 1 (i.e., n001 to n034) can be set and checked and the<br />

parameters of groups 2 and 3 (i.e., n035 to n049 and n050 to n108) can be only<br />

checked.<br />

2 The parameters of groups 1 and 2 can be set and checked and the parameters of group<br />

3 can be only checked.<br />

3 The parameters of groups 1, 2, and 3 can be set and checked.<br />

6 All parameters will be set to default-set values.<br />

7 All parameters will be initialized with a three-wire sequence. (see note 2)<br />

Note<br />

Note<br />

1. Do not set n001 to any value other than the above.<br />

2. Refer to n035 on below for the 3-wire sequence.<br />

n002<br />

Operation Mode Selection<br />

Setting range 0 to 3 Unit --- Default setting<br />

• The Inverter has four operation modes. Refer to the following table<br />

and select one of the modes with n002.<br />

Set Values<br />

Set<br />

value<br />

Run command Frequency reference Operation mode indicator of Digital<br />

Operator<br />

Remote operation Analog input<br />

0 Digital Operator Digital Operator Not lit Not lit<br />

1 Control circuit terminals<br />

Digital Operator Lit Not lit<br />

2 Digital Operator Control circuit terminals<br />

(see note 2)<br />

Not lit<br />

Lit<br />

3 Control circuit terminals<br />

Control circuit terminals<br />

(see note 2)<br />

Lit<br />

Lit<br />

1<br />

3