OMRON Sysdrive 3G3HV - Detector Cooling Section
OMRON Sysdrive 3G3HV - Detector Cooling Section
OMRON Sysdrive 3G3HV - Detector Cooling Section
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Function<br />
No.<br />
n095<br />
n096<br />
n097<br />
n098<br />
n099<br />
n100<br />
n101<br />
n102<br />
Name<br />
Energysaving<br />
control<br />
Energysaving<br />
control<br />
selection<br />
Energysaving<br />
coefficient<br />
K2<br />
Energysaving<br />
voltage<br />
lower<br />
limit for 60<br />
Hz<br />
Energysaving<br />
voltage<br />
lower<br />
limit for 6<br />
Hz<br />
Mean power<br />
time<br />
Search<br />
control voltage<br />
limit<br />
Search<br />
control voltage<br />
step<br />
when 100%<br />
Search<br />
control voltage<br />
step<br />
when 5%<br />
Description<br />
0: Inhibits the Inverter from performing<br />
energy-saving control.<br />
1: Permits the Inverter to perform energysaving<br />
control.<br />
Set coefficient so that maximum motor efficiency<br />
will be obtained.<br />
Set lower limits of energy-saving control<br />
output voltage in 1% units at 6 Hz and<br />
60 Hz based on motor rated voltage set<br />
with n011 as 100%, in which case, lower<br />
limit of energy-saving g control output voltage<br />
will be on a straight line linking values<br />
set with n097 and n098 if energy-saving<br />
control output frequency is between 6 and<br />
60 Hz.<br />
Set time to calculate mean output power<br />
of Inverter performing energy-saving control.<br />
Time (ms) = 25 x n099<br />
Set range of variable voltage in 1% units<br />
to be used by Inverter in search control<br />
mode based on rated motor input voltage<br />
as 100%.<br />
Search operation function will be invalid if<br />
n101 is set to 0.<br />
Set range of variable voltage in 1% units<br />
to be used by Inverter in search control<br />
mode with 100% search operation start<br />
voltage based on rated motor input voltage<br />
as 100%.<br />
Set range of variable voltage in 1% units<br />
to be used by Inverter in search control<br />
mode with 5% search operation start voltage<br />
based on rated motor input voltage as<br />
100%.<br />
Not used n103 Not used Do not change setting. [1]<br />
n104 Not used Do not change setting. [1]<br />
n105 Not used Do not change setting. [0]<br />
n106 Not used Do not change setting. [0]<br />
n107 Not used Do not change setting. [2]<br />
n108 Not used Do not change setting. [1]<br />
Setting<br />
range<br />
0, 1<br />
[0]<br />
0.00 to<br />
655.0<br />
[See<br />
note]<br />
0 to<br />
120<br />
[50]<br />
0 to 25<br />
[12]<br />
1 to<br />
200<br />
1<br />
0 to<br />
100<br />
0<br />
0.0 to<br />
10.0<br />
[0.5]<br />
0.0 to<br />
10.0<br />
[0.2]<br />
User<br />
setting<br />
Note Default settings vary with the Inverter model.