• Select with n070 a method to process the overvoltage error of the Inverter<br />

decelerating the motor.<br />

Set Values<br />

Set<br />

Description<br />

value<br />

0 Inhibits deceleration stall prevention from functioning.<br />

1 Permits deceleration stall prevention to function.<br />

Note<br />

Note<br />

1. Be sure to set n070 to 0 if the Braking Resistor Unit is connected to the Inverter, otherwise<br />

the Braking Resistor Unit will not work.<br />

2. The Inverter will automatically extend time to decelerate the motor so that no overvoltage<br />

error will result if n070 is set to 1.<br />

Operation Example<br />

Output<br />

frequency<br />

Deceleration time is controlled<br />

so that no overvoltage error will<br />

result.<br />

Deceleration time<br />

(Set value)<br />

n071<br />

Accelerating Stall Prevention Operation Level<br />

Setting range 30 to 200 Unit % (Rated output<br />

current ratio)<br />

Default setting<br />

170<br />

n072<br />

Operating Stall Prevention Operation Level<br />

Setting range 30 to 200 Unit % (Rated output<br />

current ratio)<br />

Default setting<br />

160<br />

• The parameters n071 and n072 are used to lower the output frequency<br />

to levels to enable the Inverter to continue operating the motor without<br />

stalling.