Indicator Item Function<br />

Fref Speed setting/Monitor The frequency reference can be set or monitored. The<br />

unit to be used can be set with n024.<br />

Fout<br />

Iout<br />

Output frequency<br />

monitor<br />

Output current<br />

monitor<br />

The output frequency can be monitored. The setting<br />

unit can be set with n024.<br />

The output current can be monitored in 0.1-A units.<br />

kWout Output power monitor The output power can be monitored in 0.1-kW units.<br />

F/R<br />

Operator<br />

forward/reverse<br />

selection<br />

The forward or reverse rotation of the motor can be set<br />

or checked. This item can be set with the Digital<br />

Operator only.<br />

Montr Monitor selection Thirteen items can be monitored.<br />

Accel<br />

Decel<br />

Vmtr<br />

Acceleration time<br />

setting<br />

Deceleration time<br />

setting<br />

Motor rated voltage<br />

setting<br />

Acceleration time 1 can be set or checked with n019 in<br />

1-s units if acceleration time 1 is set to 1,000 or a<br />

larger value and 0.1-s units if acceleration time 1 is set<br />

to a value less than 1,000.<br />

Deceleration time 1 can be set or checked with n020 in<br />

1-s units if the deceleration time is set to 1,000 or a<br />

larger value and 0.1-s units if the deceleration time is<br />

set to a value less than 1,000.<br />

The rated input voltage of the motor can be set with<br />

n011 while the Inverter is not running.<br />

V/F V/f pattern selection The V/f pattern can be set with n010 while the Inverter<br />

is not running.<br />

Fgain<br />

Fbias<br />

FLA<br />

Frequency reference<br />

gain<br />

Frequency reference<br />

bias<br />

Motor rated current<br />

setting<br />

The frequency reference gain can be set with n046<br />

while the Inverter is not running.<br />

The frequency reference bias can be set with n047<br />

while the Inverter is not running.<br />

The rated input current of the motor can be set with<br />

n032 while the Inverter is not running.<br />

PID PID control selection The PID control function can be selected with n084<br />

while the Inverter is not running.<br />

kWsav<br />

PRGM<br />

Energy-saving control<br />

selection<br />

Constant setting<br />

mode<br />

The energy-saving control function can be selected<br />

with n095 while the Inverter is not running.<br />

All parameters can be set or checked.