Indicator Item Function<br />
Fref Speed setting/Monitor The frequency reference can be set or monitored. The<br />
unit to be used can be set with n024.<br />
Fout<br />
Iout<br />
Output frequency<br />
monitor<br />
Output current<br />
monitor<br />
The output frequency can be monitored. The setting<br />
unit can be set with n024.<br />
The output current can be monitored in 0.1-A units.<br />
kWout Output power monitor The output power can be monitored in 0.1-kW units.<br />
F/R<br />
Operator<br />
forward/reverse<br />
selection<br />
The forward or reverse rotation of the motor can be set<br />
or checked. This item can be set with the Digital<br />
Operator only.<br />
Montr Monitor selection Thirteen items can be monitored.<br />
Accel<br />
Decel<br />
Vmtr<br />
Acceleration time<br />
setting<br />
Deceleration time<br />
setting<br />
Motor rated voltage<br />
setting<br />
Acceleration time 1 can be set or checked with n019 in<br />
1-s units if acceleration time 1 is set to 1,000 or a<br />
larger value and 0.1-s units if acceleration time 1 is set<br />
to a value less than 1,000.<br />
Deceleration time 1 can be set or checked with n020 in<br />
1-s units if the deceleration time is set to 1,000 or a<br />
larger value and 0.1-s units if the deceleration time is<br />
set to a value less than 1,000.<br />
The rated input voltage of the motor can be set with<br />
n011 while the Inverter is not running.<br />
V/F V/f pattern selection The V/f pattern can be set with n010 while the Inverter<br />
is not running.<br />
Fgain<br />
Fbias<br />
FLA<br />
Frequency reference<br />
gain<br />
Frequency reference<br />
bias<br />
Motor rated current<br />
setting<br />
The frequency reference gain can be set with n046<br />
while the Inverter is not running.<br />
The frequency reference bias can be set with n047<br />
while the Inverter is not running.<br />
The rated input current of the motor can be set with<br />
n032 while the Inverter is not running.<br />
PID PID control selection The PID control function can be selected with n084<br />
while the Inverter is not running.<br />
kWsav<br />
PRGM<br />
Energy-saving control<br />
selection<br />
Constant setting<br />
mode<br />
The energy-saving control function can be selected<br />
with n095 while the Inverter is not running.<br />
All parameters can be set or checked.