- Page 1 and 2:
Function The 3G3HV High-capacity Ge
- Page 3 and 4:
• Two acceleration times and two
- Page 5 and 6:
Digital Operator Easy-setting indic
- Page 7 and 8:
3G3HV-A2110/-A2150/-A4110/-A4150 E
- Page 9 and 10:
3G3HV-B2750/-B411K/-B416K External
- Page 11 and 12:
Installation Conditions Cautions a
- Page 13 and 14:
Wiring Cautions and Warnings ! WAR
- Page 15 and 16:
• Do not mount the front cover wi
- Page 17 and 18:
400-V Class Model 3G3HV- A4037 to A
- Page 19 and 20:
Standard Connection Diagram For In
- Page 21 and 22:
Wiring Around the Main Circuit Syst
- Page 23 and 24:
Voltage class Model Terminal Termin
- Page 25 and 26:
Round Solderless Terminals and Tigh
- Page 27 and 28:
peak current may flow through the i
- Page 29 and 30:
inrush current will actuate the ove
- Page 31 and 32:
• When using more than one Invert
- Page 33 and 34:
atio of harmonics in the output cur
- Page 35 and 36:
Do not ground the secondary winding
- Page 37 and 38:
200-V Class with 3.7- to 7.5-kW Out
- Page 39 and 40:
Preparation Procedure Installation
- Page 41 and 42:
Nomenclature Easy-setting indicator
- Page 43 and 44:
Indicator Item Function Fref Speed
- Page 45 and 46:
Monitor Monitor item No. U-01 Frequ
- Page 47 and 48:
Check the rated input voltage of th
- Page 49 and 50:
Change the frequency reference and
- Page 51 and 52:
Set Values Set value Run command Fr
- Page 53 and 54:
n027 Frequency Reference 3 Setting
- Page 55 and 56:
n039 Multi-function Input 5 (S6) Se
- Page 57 and 58:
Select one of the 15 V/f patterns p
- Page 59 and 60:
n012 Maximum Frequency (FMAX) Setti
- Page 61 and 62:
Energy-saving Mode The Inverter in
- Page 63 and 64:
Note speed motors (e.g., spindle mo
- Page 65 and 66:
does not save unnecessary power sup
- Page 67 and 68:
PID Control PID (proportional, inte
- Page 69 and 70:
PID Control Function Refer to the f
- Page 71 and 72:
Set Values • The parameters n086,
- Page 73 and 74:
PID Parameters The following can be
- Page 75 and 76:
Suppression of Short-cycle Vibratio
- Page 77 and 78:
Function No. Name Description Setti
- Page 79 and 80:
Function No. Name Description Setti
- Page 81 and 82:
Group 2: n035 to n049 Function No.
- Page 83 and 84:
Function Analog monitor function se
- Page 85 and 86:
Function No. Name Description Setti
- Page 87 and 88:
Function I/O phase loss detection N
- Page 89 and 90:
Function No. Name Description Setti
- Page 91 and 92:
Note 1. Do not set n001 to any valu
- Page 93 and 94:
Set Values Set value 0 The motor ca
- Page 95 and 96:
Characteristics of V/f Patterns Ge
- Page 97 and 98:
Note The V/f pattern will be a stra
- Page 99 and 100:
n029 Setting range Inching Frequenc
- Page 101 and 102:
Set Values Set Description value 0
- Page 103 and 104:
2-wire Sequence (n035 = 0) Wiring E
- Page 105 and 106:
Acceleration/Deceleration Time Swit
- Page 107 and 108:
Inverter Overheat Warning (Set Valu
- Page 109 and 110:
• The functions of multi-function
- Page 111 and 112:
Optional Frequency Detection: Outpu
- Page 113 and 114: Note 2. To permit the Inverter to o
- Page 115 and 116: n Carrier 0frequency (fc) 5 2.5 kHz
- Page 117 and 118: When the Inverter is in normal oper
- Page 119 and 120: n066 • Set with n065 DC control t
- Page 121 and 122: • Set with n071 and n072 current
- Page 123 and 124: Set Values Set Description value 0
- Page 125 and 126: Protective and Diagnostic Functions
- Page 127 and 128: Data display rh rr Description Brak
- Page 129 and 130: Data display %h3 flashing %l3 flash
- Page 131 and 132: verter if n002 is set to 0 or 2 or
- Page 133 and 134: Controller Receives Noise When Inve
- Page 135 and 136: Maintenance and Inspection Caution
- Page 137 and 138: Specifications of Inverters General
- Page 139 and 140: Control Characteristics Model 3G3HV
- Page 141 and 142: 3G3HV-PCMA2 Voltage/Current Convers
- Page 143 and 144: External Dimensions 75 min. 120 min
- Page 145 and 146: 3G3IV-PJVOP95 Analog Operator (Mini
- Page 147 and 148: 3G3IV-PLKEB Braking Resistor Unit T
- Page 149 and 150: 3G3IV-PUZBAB A MH AC Reactor Connec
- Page 151 and 152: Dimensions A B B1 C D E F H J K L M
- Page 153 and 154: External Dimensions Model 3G3IV- Ap
- Page 155 and 156: 3G3IV-PLF Output Noise Filter (Toki
- Page 157 and 158: Notes on Using the Inverter for a M
- Page 159 and 160: Motor Burnout Due to Insufficient D
- Page 161 and 162: Voltage Enclosure rating Max. motor
- Page 163: Function No. Name Description Setti
- Page 167 and 168: Group 2: n035 to n049 Function No.
- Page 169 and 170: Function Analog monitor function se
- Page 171 and 172: Function No. Name Description Setti
- Page 173 and 174: Function No. Name Description Setti
- Page 175 and 176: Function No. n095 n096 n097 n098 n0