Set the rotation direction of the motor with n006 so that the motor will rotate in the set direction<br />

when the reverse rotation command is input or set n006 so that the reverse rotation<br />

command will be ignored.<br />

n005<br />

Forward/Reverse Rotation Selection<br />

Setting range 0, 1 Unit --- Default setting<br />

0<br />

Set Values<br />

Set<br />

Description<br />

value<br />

0 The motor seen from the load side rotates counterclockwise.<br />

1 The motor seen from the load side rotates clockwise.<br />

n006<br />

Reverse Rotation-inhibit Selection<br />

Setting range 0, 1 Unit --- Default setting<br />

0<br />

Set Values<br />

Set<br />

value<br />

0 The motor can rotate reversely.<br />

1 The motor cannot rotate reversely.<br />

Description<br />

Multi-function Input Selection (n035 to n039)<br />

Set n035 to n039 so that the Inverter can use multi-function input terminals 2 to 6 to perform<br />

the following.<br />

Three-wire sequential operation<br />

Multi-step operation<br />

Inching operation<br />

Operation using acceleration time 2 and deceleration time 2<br />

Refer to <strong>Section</strong> 3–5–3 List of Parameters for details.<br />

n035<br />

Multi-function Input 1 (S2)<br />

Setting range 0 to 24 Unit --- Default setting<br />

n036<br />

Multi-function Input 2 (S3)<br />

Setting range 2 to 24 Unit --- Default setting<br />

n037<br />

Multi-function Input 3 (S4)<br />

Setting range 2 to 24 Unit --- Default setting<br />

n038<br />

Multi-function Input 4 (S5)<br />

Setting range 2 to 24 Unit --- Default setting<br />