11.07.2015 Views

transport of dangerous goods and risk management - Kirilo Savić

transport of dangerous goods and risk management - Kirilo Savić

transport of dangerous goods and risk management - Kirilo Savić

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TRANSPORT OF DANGEROUS GOODS AND RISK MANAGEMENT 89Figure 6. Schematic <strong>of</strong> universal battery powered distribution boxThis part <strong>of</strong> the device facilitates the power supply <strong>of</strong> the coastal measuring telecommunication unit from differentpower sources:supply from network single-phase voltage <strong>of</strong> 220 V, 50 Hz, over the rectifier which produces directvoltages <strong>of</strong> 12V <strong>and</strong> 24 V. At the same time, this voltage is used for recharging batteries, as reserve powersupply. The switch behind the rectifier is used to select the voltage <strong>of</strong> 12V or 24 V, whereas it is placed inthe „0“ position when there is no network supply;supply from solar panel with the voltage <strong>of</strong> 12V or 24V, if there are no other power sources. A voltageregulator led from the solar panel is placed inside the distribution box. At the same time, this voltage is usedto recharge the battery;supply from gel battery, with the voltage <strong>of</strong> 12V or 24V <strong>and</strong> capacity <strong>of</strong> 15-40 Ah. The battery is used asreserve power supply , <strong>and</strong> with solar panels, it is used for charging the device during the night. Gel batterydoes not require any special maintenance <strong>and</strong> it does not cause any damaging vapours which could erodethe electric parts inside the box;supply over external source <strong>of</strong> 12V or 24V (if one exists) which is facilitated by the connection built in forthis type <strong>of</strong> power supply.Inside the distribution box there are diodes which are used to protect certain systems from destruction caused by thechanges in polarity <strong>of</strong> the supply voltage or emptying <strong>of</strong> the battery due to the short circuit in any part <strong>of</strong> the device.Coastal measuring telecommunication unitExternal <strong>and</strong> internal view <strong>of</strong> the coastal measuring telecommunication unit are shown on Figures 7 <strong>and</strong> 8.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!