VMSC - Voice Mail Domain (VMD) Configuration<br />

Serviceability - General Tab<br />

Use the Serviceability dialog box, General tab to configure the ability of the MAS to<br />

generate logs and notifications related to system errors and alarms. These notifications<br />

are sent out using either INADS or SNMP traps to a network management server. You<br />

can also control voice port service on the MAS.<br />

Launching the Screen<br />

1. In the Voice Mail System Configuration window, click the voice mail<br />

domain.<br />

2. Double-click Serviceability. The system displays the Serviceability<br />

dialog box for the selected VMD, with the General tab active.<br />

Configuring the Screen Controls<br />

! Send alarms using Select whether you want to send alarms using None,<br />

SNMP or INADS.<br />

— None (Default) Select so that no alarm notifications are sent out.<br />

You can still, however, view alarm logs on the MAS.<br />

Note: These fields in the tab are then grayed out: Suppress alarm<br />

notifications, Send notifications when all alarms are<br />

cleared, Send alarm at this level or higher, and Product<br />

identifier.<br />

— SNMP Select to send Alarm traps to a network management station<br />

using SNMP.<br />

Notes:<br />

! It is your responsibility to provide and provision your SNMP<br />

network management station and configure it to receive the<br />

traps from the MAS<br />

! If you select this option, you should configure the SNMP tab.<br />

See Serviceability - SNMP Tab on page 3-140.<br />

— INADS Select to use the <strong>Avaya</strong> Initialization and <strong>Administration</strong><br />

System (INADS) tool to send alarm notifications to an alarm<br />

collection server for analysis and corrective action.<br />

Note: You must also configure the individual MASs for INADS. See<br />

MAS - Serviceability Dialog Box on page 4-59.<br />

! Suppress alarm notifications (Default Off) Select to temporarily suppress<br />

alarm notifications.<br />

<strong>Avaya</strong> Modular Messaging Release 3.1 with the <strong>Avaya</strong> MSS<br />

February 2007 MAS <strong>Administration</strong> <strong>Guide</strong><br />

3–137