MAS Alarms<br />

MAS Alarm - TS PERF 14<br />

Level<br />

Major.<br />

System Descriptor<br />

Counter (virtual bytes) for tracing server process greater than 1.8 GB<br />

Description<br />

This alarm indicates that the counter (in virtual bytes) for the MM Tracing Server<br />

service is greater than 1.8 GB. This means that the tracing server process has<br />

exceeded the recommended virtual memory usage.<br />

This problem may be caused by memory leaks in the system. When this happens, the<br />

system can become unstable, and one or more processes or services can begin to fail.<br />

Repair Procedure<br />

To recover from this alarm, you must stop and restart the MM Tracing Server service.<br />

See Appendix C, Stopping and Restarting Modular Messaging Services.<br />