11.07.2015 Views

PDF user manual for CopperEdge 150

PDF user manual for CopperEdge 150

PDF user manual for CopperEdge 150

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

&RQILJXULQJDQ,08;%XQGOHIn general, the procedure <strong>for</strong> setting up an IMUX bundle andconfiguring it is the same as <strong>for</strong> an individual DSL port, butthere are a few special considerations.When choosing which DSL ports to put into an IMUX bundle,note that they can be on the same DSL Module or on differentones, but all ports in the bundle must be on the same CE<strong>150</strong>.1. Using cmHDSLModem, set the rates at which you wanteach of the ports in the bundle to operate.2. For best multilink per<strong>for</strong>mance, set the two lines to thesame speed. For example, if you want approximately2000 Kbps throughput, it is better to set both lines at1040 Kbps (<strong>for</strong> a total of 2080) than it is to set one at1568 Kbps and the other at 416 Kbps (<strong>for</strong> a total of1984).CRAFT> set cmhdsl [1.5.1] datarate=1040Set SuccessfulCRAFT> set cmhdsl [1.5.2] datarate=1040Set Successful3. Using cmBundle, create the bundle and enter the PIIsof the DSL ports on the CE<strong>150</strong> that you want to assignto the bundle. You can enter all of the ports in thebundle with one command or you can enter one andthe others later or you can create the bundle and addno ports initially.CRAFT> set cmbundle [1.51.1] member1pii=1.5.1member2pii=1.5.2Set Successful4. If the CPE connected to the bundle is an IMUX CPE,then it will train normally, first on the Member1PIIport, and then on the Member2PII port.5. If the bundle is miswired or misconfigured, an alarmwill be generated and a trap sent. If the configurationand wiring are correct, but there is no CPE connectedor trained, the member ports in that bundle will showan endpoint ID consisting of zeros, and their status willindicate WaitForAdd. If a CPE is later connected, it willtrain normally and the member ports’ endpoint andstatus in<strong>for</strong>mation will automatically update.6. Using cmIface, set the NetModel and theEncapsulationType <strong>for</strong> the IMUX bundle. TheCopperRocket 202 works only with the Cross-Connectnetmodel. Also, if you want to change the default <strong>for</strong>Service Class, you can do so at the same time. Forexample:CRAFT> set cmiface [1.51.1] netmodel=cross-connectencapsulationtype=q922Set Successful&RSSHU(GJH,QVWDOODWLRQDQG2SHUDWLQJ*XLGH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!