11.07.2015 Views

PDF user manual for CopperEdge 150

PDF user manual for CopperEdge 150

PDF user manual for CopperEdge 150

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Ground the CE<strong>150</strong> ChassisWhen operating on -48 VDC power, the CE<strong>150</strong> chassis must beconnected to a professionally installed Protective Earth, whichis independent of the AC Mains Power Earth.Specific instructions <strong>for</strong> installation of Protective Earth connectionsare contained in the National Electric Code <strong>for</strong> the UnitedStates and Canada. The Protective Earth must be installed bya licensed and qualified electrician.Connection of the CE<strong>150</strong> chassis to the grounding electrodemust be made in con<strong>for</strong>mance to the local and national regulationsand may only be per<strong>for</strong>med by trained and licensed servicepersonnel. The grounding electrode conductor must besized equivalent to a stranded 12 AWG wire.DC Power ConnectionConnection of the -48 VDC power system to the CE<strong>150</strong> is providedby a barrel-type connector, as shown in the previous illustration.To connect the -48 VDC power to the CE<strong>150</strong>, follow these steps:1. Loosen the screws in the barrel-type terminals, namedJP1, <strong>for</strong> both the -48 volt line and the return line.2. Insert a red #12 AWG stranded copper wire <strong>for</strong> the -48volt line into the hole in the bottom of the barrelmarked -48V.3. Connect the other end of the red #12 AWG strandedcopper wire to the -48 VDC power source.4. Insert a black #12 AWG stranded copper wire <strong>for</strong> the48 volt return connection into the hole in the bottom ofthe barrel marked RTN.5. Connect the other end of the black #12 AWG strandedcopper wire to the 48 VDC power source Returnconnection.6. Tighten both screws so the wires cannot slip out.& $ 8 7 , 2 1Reversing the polarity of the -48 VDC input connections will causedamage to the DC Power Module, requiring its return to the factory <strong>for</strong>repair. Never rely on wire color or "logic" when connecting the supplylines. Use an appropriate meter or testing device to verify the polaritybe<strong>for</strong>e connecting the DC Power Sources.&RSSHU(GJH,QVWDOODWLRQDQG2SHUDWLQJ*XLGH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!