7. At the CE<strong>150</strong> console, wait five seconds and repeat theget cmsdsltest command.The value of the integer displayed in theContinuityTestResult field should return to the valueyou noted in step 3.When using the cmSDSLTestTable <strong>for</strong> troubleshooting, the absolutenumerical values displayed in the above procedure haveno meaning in themselves, and will vary depending on thelength of the loop and a number of other physical and electricalfactors. The significant points are the change in the value as theline is monitored while being opened or shorted, and whetherand by how much the resulting values deviate from the baselinesrecorded at the time of installation. The following diagramshows the cmSDSLTest function.CO Loop(Up to 500 ft.)<strong>CopperEdge</strong>DSLAMCPESDSLMod.CPE Connection Point(On-site assistant alternately opens loopand applies short while CE200 operatorm onitors test in progress.)CO Connection Point(NearEndLoopProfile checks <strong>for</strong>shorted or open circuits up to500 ft from the SDSL port.)SDSL Loop Test Functionality&RSSHU(GJH,QVWDOODWLRQDQG2SHUDWLQJ*XLGH