11.07.2015 Views

PDF user manual for CopperEdge 150

PDF user manual for CopperEdge 150

PDF user manual for CopperEdge 150

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FRF.5 Forwarding ModeThis translation mode allows a DSL port on the CE<strong>150</strong> to receiveQ.922 HDLC frames, trans<strong>for</strong>m them into ATM AAL5PDUs, and send them to an ATM WAN interface <strong>for</strong> transmissionacross an ATM network. At the other end of the network, areverse translation allows the Q.922 HDLC frames to be recovered.To configure this mode, set the netmodel and encapsulationtype on the DSL and WAN interfaces:CRAFT> set cmiface [1.2.1.100] netmodel=cross-connectencapsulationtype=frf5CRAFT> set cmiface [1.5.1] netmodel=cross-connectencapsulationtype=q922CRAFT> set cmsubiface [1.5.1.15] destpii=1.2.1.100FRF.8 Translation and Transparent Forwarding ModesThis translation/<strong>for</strong>warding mode is <strong>for</strong> Q.922 frames beingsent to ATM VCs on an ATM network where they terminate. TheCE<strong>150</strong> decides to use translation mode or transparent modebased on the encapsulations set on the DSL VC and WAN VC.(In the Cross-Connect netmodel, DSL VC encapsulation is impliedby the DSL port encapsulation.)For instance, if the two encapsulations are the same (or if theWAN VC encapsulation is None), Transparent mode is used. Ifthey differ, the Translation mode is used. Since DSL encapsulationapplies to an entire DSL port, all DSL VCs that requiretranslation must use the same encapsulation. DSL encapsulationis not relevant or used on DSL VCs that are not translated(i.e., whose cross-connected WAN VC does not specify a translation).To configure two data VCs on one DSL port, and map them totwo WAN VCs where one has an encapsulation type of RFC-1483 and the other has an encapsulation type of None, enterthe following commands:CRAFT> set cmiface [1.2.1.1] netmodel=cross-connectencapsulationtype=rfc1483 destpii=1.4.1.19CRAFT> set cmiface [1.2.1.2] netmodel=cross-connectencapsulationtype=none destpii=1.4.1.20CRAFT> set cmiface [1.4.1] netmodel=cross-connectencapsulationtype=q.922CRAFT> set cmsubiface [1.4.1.19] destpii=1.2.1.1CRAFT> set cmsubiface [1.4.1.20] destpii=1.2.1.2After configuration, WAN VC 1.3.1.1 has a <strong>for</strong>warding mode ofFRF8-1490-1483, while WAN VC 1.3.1.2 has a <strong>for</strong>wardingmode of VC-VC-payload.&RSSHU(GJH,QVWDOODWLRQDQG2SHUDWLQJ*XLGH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!