&RQILJXULQJ)XOO,3'6//LQNVYou configure DSL links <strong>for</strong> Full-IP routing as described in theprevious chapter. In brief, assign the DSL interface an IP address,optional subnet mask, and leave the DestPii object set tozero. (FarEndAddr is normally ignored on DSL links, unlessconfigured <strong>for</strong> policy routing over Ethernet). Be sure to configurethe EncapsulationType, NetModel, and any other mandatorysettings, as well. For example:Group: cmIfaceTableInstance: [1.4.1.0]PII = 1.4.1.0IfIndex = 1.4.1.0Name= System-assigned port nameGroupName= User-Group ID StringAdditionalInfo= User-defined text stringNetModel= IPIpAddr = 192.168.1.1NetMask = 255.255.255.0MacAddr= 0.60.58.0.0.bBurnedInMacAddr= 0.60.58.0.0.bFarEndAddr = 0.0.0.0DestPii = 0.0.0.0CMCPCompatible= YesEncapsulationType = rfc1483FwdMode= Full-IPPix = 88You can change a policy-routed DSL link to full-IP at any timeby setting destPii to 0.0.0.0. The fwdMode field will display themode (Full-IP or IP Policy) based on the setting of the destPiiobject.&RSSHU(GJH,QVWDOODWLRQDQG2SHUDWLQJ*XLGH