Wiring diagram<br />

SM 321<br />

DI 4 x NAMUR<br />

Input 0<br />

Input 1<br />

Input 2<br />

Input 3<br />

X 2<br />

3 4<br />

321-7RD00-0AB0<br />

SF<br />

I/O Modules with Intrinsically-Safe Signals<br />

C79000-G7076-C152-04<br />

F0<br />

0<br />

F1<br />

1<br />

F2<br />

2<br />

F3<br />

3<br />

Fig. 2-1 shows the terminal diagram of the digital input module SM 321;<br />

DI 4 x NAMUR.The block diagram and detailed technical data can be found<br />

on the following pages.<br />

Channel number<br />

1<br />

2<br />

3 8.2 V<br />

4<br />

18<br />

1K<br />

19<br />

20<br />

L<br />

5<br />

1K<br />

6<br />

7 8.2 V<br />

8<br />

9<br />

1K<br />

10<br />

11<br />

12 8.2 V<br />

13<br />

14<br />

1K<br />

15<br />

16 8.2 V<br />

17<br />

M<br />

Terminal diagram for<br />

NAMUR sensor with<br />

monitoring for<br />

– wire break<br />

– short-circuit<br />

SF group fault [red] KF (0...3) channel-specific fault indication [red]<br />

0...3 status indication [green]<br />

1<br />

2<br />

3 8.2 V<br />

4 10k<br />

5<br />

1k<br />

9<br />

1K<br />

10<br />

L<br />

1K<br />

6<br />

7 8.2 V<br />

8 10k<br />

11<br />

12 8.2 V<br />

13<br />

14<br />

1K<br />

15<br />

16<br />

17<br />

18<br />

1K<br />

19<br />

20 M<br />

Fig. 2-1 Wiring diagram of digital input module SM 321; DI 4 x NAMUR<br />

Notes on<br />

intrinsically-safe<br />

installation<br />

Power supply for a<br />

intrinsically-safe<br />

structure<br />

SIMATIC S7 Ex Digital Modules<br />

Terminal diagram for<br />

contacts<br />

(connection<br />

variants)<br />

Contact with monitoring<br />

for<br />

– wire break<br />

– conductor short-circuit<br />

(only if resistors<br />

connected directly at<br />

contact)<br />

Contact with monitoring<br />

for<br />

– wire break<br />

(only if resistor<br />

connected directly at<br />

contact)<br />

Contact<br />

without monitoring<br />

You must connect the DM 370 dummy module between the CPU or IM 153-2<br />

(distributed configuration) and the Ex I/O modules whose signal cables lead into<br />

the hazardous area. In a distributed configuration with an active backplane bus,<br />

you should use the explosion-proof partition instead of the dummy module.<br />

Additional information on system design can be found in Section 1.3 - 1.5.<br />

In order to maintain the dearances and creepage distances, L+ / M must be<br />

routed via the line chamber LK393 when operating modules with signal<br />

cables that lead to the hazardous location, see Section 1.2.<br />

2-3