DIVISION 1 SPECIFICATIONS<br />

SECTION 1045 CUTTING AND PATCHING<br />

Exhibit 2<br />

Page 220 of 379<br />

PART 2 - PRODUCTS<br />

2.01 MATERIALS<br />

A. Use materials for cutting <strong>and</strong> patching that are identical to existing materials. If<br />

identical materials are not available, or cannot be used, use materials that match<br />

existing adjacent surfaces to fullest extent possible with regard to visual effect.<br />

B. Use materials for cutting <strong>and</strong> patching that will result in equal-or-better<br />

performance characteristics.<br />

C. Comply with specifications <strong>and</strong> st<strong>and</strong>ards for each specific product involved.<br />

PART 3 - EXECUTION<br />

3.01 EXAMINATION<br />

A. Before cutting, examine surfaces <strong>and</strong> conditions under which Work is to be<br />

performed. If unsafe or otherwise unsatisfactory conditions are encountered,<br />

take corrective action before proceeding with Work.<br />

B. Before start of cutting Work, meet at Work Site with all parties involved in cutting<br />

<strong>and</strong> patching, including mechanical <strong>and</strong> electrical trades. Review areas of<br />

potential interference <strong>and</strong> conflict <strong>between</strong> various trades. Coordinate layout of<br />

Work <strong>and</strong> resolve potential conflict before proceeding with Work.<br />

3.02 PREPARATION<br />

A. Provide adequate temporary support as necessary to assure structural value or<br />

integrity of affected portion of Work.<br />

B. Protect other Work during cutting <strong>and</strong> patching to prevent damage. Provide<br />

protection from adverse weather conditions for that part of project that may be<br />

exposed during or after cutting <strong>and</strong> patching operations.<br />

C. Avoid interference with use of adjoining areas or interruption of free passage to<br />

adjoining areas.<br />

D. Take precautions not to cut existing pipe, conduit, or duct serving building but<br />

schedule to be relocated until provisions have been made to bypass them.<br />