DIVISION 1 SPECIFICATIONS<br />

SECTION 01050 FIELD ENGINEERING<br />

Exhibit 2<br />

Page 223 of 379<br />

PART 1 - GENERAL<br />

1.01 REQUIREMENTS INCLUDED<br />

A. Data furnished by the <strong>COUNTY</strong>, the CPM or the CONSULTANT will locate <strong>and</strong><br />

reference survey base lines <strong>and</strong> will establish benchmarks at appropriate<br />

intervals along the base line to facilitate the proper layout of the Work by the<br />

CONTRACTOR. The CONTRACTOR shall preserve all reference points <strong>and</strong><br />

benchmarks furnished by the <strong>COUNTY</strong>, the CPM or the CONSULTANT.<br />

B. The CONTRACTOR shall furnish all lines, grades, <strong>and</strong> measurements necessary<br />

to the proper prosecution <strong>and</strong> control of the Work under these Contract<br />

Documents. The Work shall include performing all calculations required <strong>and</strong><br />

setting all control needed, such as offsets, reference points, <strong>and</strong> other reference<br />

marks or points necessary to provide lines <strong>and</strong> grades for construction. The data<br />

furnished by the <strong>COUNTY</strong>, CPM or the CONSULTANT will establish horizontal<br />

<strong>and</strong> vertical control points only. The CONTRACTOR is thereafter responsible to<br />

maintain these control points for use by subsequent contractors.<br />

C. Horizontal <strong>and</strong> Vertical Control: The CONTRACTOR shall also establish<br />

horizontal <strong>and</strong> vertical controls for carrying out utility relocation or construction<br />

Work when such Work is included in the Contract.<br />

D. The CONTRACTOR shall establish the building grades, lines, levels, column,<br />

wall <strong>and</strong> partition lines required.<br />

E. The CONTRACTOR shall calculate <strong>and</strong> measure required dimensions indicated<br />

within recognized tolerances <strong>and</strong> should not scale drawings to determine<br />

dimensions.<br />

F. The CONTRACTOR shall advise subcontractors performing Work of marked<br />

lines <strong>and</strong> levels provided for use in layout of Work.<br />

1.02 SURVEY<br />

A. Surveyor: Engage L<strong>and</strong> Surveyor or Professional Engineer experienced <strong>and</strong><br />

specializing in l<strong>and</strong> survey Work, who is registered by the State of Florida to<br />

perform specified service.<br />

B. The CONTRACTOR shall retain a competent Registered Professional Engineer<br />

or Registered L<strong>and</strong> Surveyor, who shall establish the exterior lines <strong>and</strong> required<br />

elevations of all buildings <strong>and</strong> structures to be erected on the site <strong>and</strong> shall<br />

establish sufficient lines <strong>and</strong> grades for the construction of associated Work such<br />

as, but not limited to, roads, utilities <strong>and</strong> site grading. The Engineer or L<strong>and</strong><br />

Section 01050 Field Engineering Page 18