DIVISION 1 SPECIFICATIONS<br />

SECTION 01340 – SHOP DRAWINGS, PRODUCT DATA AND SAMPLES<br />

samples to subcontractors, suppliers, fabricators, manufacturers,<br />

installers, governing authorities, <strong>and</strong> others as required for proper<br />

performance of the Work. Show final distribution on transmittal forms.<br />

4. Mock-Ups: Mock-ups are special form of samples, which are too<br />

large or otherwise inconvenient for h<strong>and</strong>ling in specified manner for<br />

transmittal of sample submittals. Mock-ups <strong>and</strong> similar samples specified<br />

in individual Work sections recognized as a special type of sample.<br />

Comply with requirements for sample to greatest extent possible, <strong>and</strong><br />

process transmittal forms to provide records of activity.<br />

a. Field Samples:<br />

E. MISCELLANEOUS SUBMITTALS:<br />

Exhibit 2<br />

Page 280 of 379<br />

(1) Construct mock-up for CONSULTANT’s <strong>and</strong> CPM’s visual<br />

examination, for quality control, <strong>and</strong> performance of<br />

required testing.<br />

(2) Erect at location acceptable to CPM.<br />

(3) Size of Area: As specified in respective Specification<br />

Section.<br />

(4) Fabricate each sample <strong>and</strong> mock-up complete <strong>and</strong> finished<br />

using materials, fabrication, <strong>and</strong> installation methods<br />

identical with those indicated for Work.<br />

(5) Remove mock-ups at conclusion of Work or when<br />

acceptable to CPM if not incorporated into Work.<br />

1. Inspection <strong>and</strong> Test Reports: Classify each inspection <strong>and</strong> test report as<br />

being either “shop drawings” or “product data” depending on whether the<br />

report is specially prepared for the project, or a st<strong>and</strong>ard publication of<br />

workmanship control testing at the point of production. Process<br />

inspection <strong>and</strong> test reports accordingly.<br />

2. Warranties: Refer to Section 01740 - WARRANTIES, for specific general<br />

requirements on warranties, product bonds, workmanship bonds <strong>and</strong><br />

maintenance agreements. In addition to copies desired for the<br />

CONTRACTOR’s use, furnish two (2) executed copies of such<br />

warranties, bonds, or agreements. Provide two (2) additional copies<br />

where required for maintenance manuals.<br />

3. Survey Data: Refer to Section 01040 - PROJECT COORDINATION, for<br />

specific general requirements on property surveys, field measurements,<br />

<strong>and</strong> quantitative records of actual Work, damage surveys <strong>and</strong> similar data<br />

required by the individual sections. None of the specified copies will be<br />

returned.<br />

4. St<strong>and</strong>ards: Where submittal of a copy of a st<strong>and</strong>ard is indicated, <strong>and</strong><br />

except where copies of st<strong>and</strong>ards are specified as an integral part of a<br />

“Product Data” submittal, submit a single copy of st<strong>and</strong>ards for the<br />

CONSULTANT’s use. Where workmanship, whether at the project site or<br />

elsewhere is governed by a st<strong>and</strong>ard, furnished additional copies of the<br />

st<strong>and</strong>ard to fabricators, installers <strong>and</strong> others involved in the performance<br />

of the Work.<br />

5. Closeout Submittals: Refer to Section 01770 - PROJECT CLOSEOUT,<br />

<strong>and</strong> to individual section of these specifications for specific submittal<br />