DCA TERMINAL A IMPROVEMENTS (NEAR TERM) 10 AUGUST 2012<br />

TASK ORDER 03: LOBBY IMPROVEMENTS – PKG 4 - CURBSIDE CHECK-IN<br />

RONALD REAGAN WASHINGTON NATIONAL AIRPORT<br />

PROJECT DT1203<br />

1. Joint Locations:<br />

a. Joints between different materials listed above.<br />

b. Other joints as indicated.<br />

2. Silicone Joint Sealant: Single component, nonsag, neutral curing, Class 100/50 or Single<br />

component, nonsag, neutral curing, Class 50.<br />

3. Urethane Joint Sealant: Single component, nonsag, Class 100/50 or Single component,<br />

nonsag, Class 50.<br />

4. Preformed Joint Sealant: Preformed silicone or Preformed foam.<br />

5. Joint-Sealant Color: As selected by COTR from manufacturer's full range of colors.<br />

B. Joint-Sealant Application: Interior joints in vertical surfaces and horizontal nontraffic surfaces.<br />

1. Joint Locations:<br />

a. Perimeter joints of exterior openings where indicated.<br />

b. Perimeter joints between interior wall surfaces and frames of interior doors..<br />

c. Other joints as indicated.<br />

2. Silicone Joint Sealant: Single component, nonsag, neutral curing, Class 50.<br />

3. Urethane Joint Sealant: Single component, nonsag, Class 50.<br />

4. Joint-Sealant Color: As selected by COTR from manufacturer's full range of colors.<br />

PART 4 - CONTRACTOR’S QUALITY CONTROL REQUIREMENTS<br />

4.1 GENERAL<br />

A. Comply with applicable provisions of Division 01 Section “Quality Requirements” for<br />

requirements for Contractor Quality Control Program.<br />

B. Field Quality Control:<br />

1. Field-Adhesion Testing: Field test joint-sealant adhesion to joint substrates as follows:<br />

a. Extent of Testing: Test completed and cured sealant joints as follows:<br />

1) Perform 10 tests for the first 1000 feet of joint length for each kind of<br />

sealant and joint substrate.<br />

2) Perform 1 test for each 1000 feet of joint length thereafter or 1 test per each<br />

floor per elevation.<br />

b. Test Method: Test joint sealants according to Method A, Field-Applied Sealant<br />

Joint Hand Pull Tab, in Appendix X1 in ASTM C 1193.<br />

1) For joints with dissimilar substrates, verify adhesion to each substrate<br />

separately; extend cut along one side, verifying adhesion to opposite side.<br />

Repeat procedure for opposite side.<br />

JOINT SEALANTS 07 92 00 - 10