DCA TERMINAL A IMPROVEMENTS (NEAR TERM) 10 AUGUST 2012<br />

TASK ORDER 03: LOBBY IMPROVEMENTS – PKG 4 - CURBSIDE CHECK-IN<br />

RONALD REAGAN WASHINGTON NATIONAL AIRPORT<br />

PROJECT DT1203<br />

1. Submit test reports in both printed format and an electronic format to assist the COTR in<br />

the final review process. Printed test reports shall be provided in 8-1/2 x 11-inch three<br />

ring binders. Electronic copies of the test reports shall be either in a file format that can<br />

be imported or viewed using standard office software or in a file format used by the<br />

testing software, provided the testing software program is also submitted with the raw<br />

testing files.<br />

2. Refer to the testing section of the specifications for details on the data that shall be<br />

included in the test reports.<br />

3. Submit six (6) printed copies of the test reports and six (6) electronic copies of the test<br />

reports with the testing software program on CD-ROM.<br />

N. The Contractor shall provide an "as-built" list of the initial patch cable connections that with the<br />

Schedule of Outlets will enable the COTR to trace the circuit continuity of each voice and data<br />

outlet to its point of demarcation.<br />

1.12 WARRANTY<br />

A. As specified in Division 27 Section: “Basic Telecommunication Requirements.”<br />

PART 2 - PRODUCTS<br />

2.1 GENERAL<br />

A. All equipment shall be new and unused.<br />

B. All equipment, materials, accessories, devices, and other facilities covered by this specification<br />

or noted on the Contract Drawings shall be the best suited for the intended use and shall be<br />

provided by a single manufacturer.<br />

C. Provide all components, equipment, parts, accessories and associated quantities required for<br />

complete installations and according to the manufacturer’s installation specifications. All<br />

components may not be specified herein.<br />

2.2 PRODUCTS<br />

A. Copper tie cabling: as specified in Division 27 Section “Communications Backbone Cabling.”<br />

B. Data copper terminations: as specified in Division 27 Section “Communications Backbone<br />

Cabling.”<br />

C. Patch panels: as specified in Division 27 Section “Communications Equipment Room Fittings.”<br />

D. Voice copper terminations: Division 27 Section “Communications Equipment Room Fittings.”<br />

PREMISE WIRING DISTRIBUTION SYSTEM 27 10 00 - 8