DCA TERMINAL A IMPROVEMENTS (NEAR TERM)10 AUGUST 2012<br />

TASK ORDER 03: LOBBY IMPROVEMENTS – PKG 4 -CURBSIDE CHECK-IN<br />

RONALD REAGAN WASHINGTON NATIONAL AIRPORT<br />

PROJECT DT1203<br />

a. All take-up pulleys shall be a minimum of 4” in diameter, steel, trapezoidal faced<br />

and equipped with taper-lock hubs and 1-7/16” minimum diameter AISI 1018<br />

C.R.S. shafts mounted in eccentric locking-type precision and ground flange-type<br />

ball bearing units. Pulleys shall be mounted on threaded take-up devices with steel<br />

guides and a minimum of 6” adjustment. All conveyors shall be provided with<br />

take-ups for field adjustment of a minimum of 2% of the conveyor bed length.<br />

Take-ups shall be an integral part of the drive frames on all intermediate-drive<br />

conveyors.<br />

b. All conveyor sections in excess of 50’ in length operating in tunnels or outside of<br />

the building subject to extreme temperature and humidity' changes shall be<br />

equipped with automatic take-up devices.<br />

c. All take-ups used in heavy-duty or high-speed applications shall be the same as<br />

above except shall be of 6” diameter with 1-7/16” diameter shafts.<br />

9. Bearings:<br />

a. Each roller/pulley shall be equipped with a pair of proper duty type bearings. The<br />

bearings shall be Dodge ABHS bearings, Eccentric Collar Ball bearings or as<br />

acceptable to The Authority.<br />

b. All bearings shall be lubed for life (66% grease fill) with pipe plug and pop-in end<br />

cover. Bearings shall be mounted on the outside of the conveyor frame unless<br />

clearance restrictions prohibit.<br />

c. All exposed bearings in work areas shall be equipped with bearing covers and meet<br />

OSHA requirements for employee safety. Bearing covers shall be provided on all<br />

conveyors that are in tenant work areas, accessible to tenant personnel; in public<br />

areas, and accessible to the public.<br />

d. Bearings shall have a minimum L-10 life of 70,000 hours based on the service and<br />

loading of conveyors and on the manufacturer's published data showing load rating<br />

of each bearing used.<br />

e. Bearings shall be greased when installed per manufacturer’s recommendations.<br />

D. Chutes and Slides: Where a chute or slide is indicated on the drawings or is required, it shall be<br />

constructed of 10 gauge min. galvanized steel for the bed and the sideguards shall be 12 gauge<br />

min. hot-rolled steel. Sideguards shall be 18 inches high and reinforced with stiffeners spaced<br />

at 40” maximum on center.<br />

E. Power Turns and Spiral Turns:<br />

1. Turns shall be steel frame construction, shall be ‘C’ size and the width shall match the<br />

width between sideguards of the adjacent downstream conveyor. Belt speed of turns, as<br />

measured on the centerline, shall be at least as fast as the input conveyor and the same<br />

speed or slower than the output conveyor.<br />

2. Manufacturers offering products in conformance to the specifications are:<br />

F. Belting:<br />

a. FLOmaster Division of Portec, Inc.<br />

b. Or as acceptable to The Authority.<br />

BAGGAGE HANDLING EQUIPMENT 34 77 16 - 38