DCA TERMINAL A IMPROVEMENTS (NEAR TERM) 10 AUGUST 2012<br />

TASK ORDER 03: LOBBY IMPROVEMENTS – PKG 4 - CURBSIDE CHECK-IN<br />

RONALD REAGAN WASHINGTON NATIONAL AIRPORT<br />

PROJECT DT1203<br />

D. Fire-Labeled Gasketing: Assemblies complying with NFPA 80 that are listed and labeled by a<br />

testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings<br />

indicated, based on testing according to NFPA 252.<br />

1. Test Pressure: After 5 minutes into the test, neutral pressure level in furnace shall be<br />

established at 40 inches or less above the sill.<br />

E. Replaceable Seal Strips: Provide only those units where resilient or flexible seal strips are<br />

easily replaceable and readily available from stocks maintained by manufacturer.<br />

F. Gasketing Materials: ASTM D 2000 and AAMA 701/702.<br />

G. Available Manufacturers:<br />

1. Hager Companies (HAG).<br />

2. M-D Building Products, Inc. (MD).<br />

3. National Guard Products (NGP).<br />

4. Pemko Manufacturing Co. (PEM).<br />

5. Reese Enterprises (RE).<br />

6. Sealeze; a unit of Jason Incorporated (SEL).<br />

7. Zero International (ZRO).<br />

2.13 THRESHOLDS<br />

A. Standard: BHMA A156.21. Listed under Category J in BHMA's "Certified Product Directory."<br />

B. Available Manufacturers:<br />

1. National Guard Products (NGP).<br />

2. Pemko Manufacturing Co. (PEM).<br />

3. Reese Enterprises (RE).<br />

4. Sealeze; a unit of Jason Incorporated (SEL).<br />

5. Zero International (ZRO).<br />

2.14 FABRICATION<br />

A. Manufacturer's Nameplate: Do not provide products that have manufacturer's name or trade<br />

name displayed in a visible location except in conjunction with required fire-rated labels and as<br />

otherwise approved by COTR.<br />

1. Manufacturer's identification is permitted on rim of lock cylinders only.<br />

B. Base Metals: Produce door hardware units of base metal, fabricated by forming method<br />

indicated, using manufacturer's standard metal alloy, composition, temper, and hardness.<br />

Furnish metals of a quality equal to or greater than that of specified door hardware units and<br />

BHMA A156.18. Do not furnish manufacturer's standard materials or forming methods if<br />

different from specified standard.<br />

DOOR HARDWARE 08 71 00 - 11

Hooray! Your file is uploaded and ready to be published.