DCA TERMINAL A IMPROVEMENTS (NEAR TERM)10 AUGUST 2012<br />

TASK ORDER 03: LOBBY IMPROVEMENTS – PKG 4 -CURBSIDE CHECK-IN<br />

RONALD REAGAN WASHINGTON NATIONAL AIRPORT<br />

PROJECT DT1203<br />

4. Interface connections and coordination as specified herein with the existing and new<br />

building constraints, expansion joints, signage, fire alarm and smoke detection system,<br />

and access control system.<br />

B. Related Sections:<br />

1. Fire Alarm and Smoke Detection System will be furnished and installed within the<br />

General Contract and are specified in Division 28 Section “Digital, Addressable Fire –<br />

Alarm System”. Controls interface with the BHS is described in this section.<br />

2. Control Access Security System will be furnished and installed within the General<br />

Contract and is specified in Division 28 Section “Access Control and Alarm Monitoring<br />

System”. Controls interface with the BHS is described in this section.<br />

3. Electrical requirements for general provisions, materials, and installations shall be in<br />

accordance with Division 26 Sections.<br />

C. Alternates: The straight conveyor segment of the load belt is a bid alternate.<br />

1.3 REFERENCES<br />

A. Reference Standard:<br />

1. Comply with the requirements of the reference standards noted herein, except where<br />

more stringent requirements are listed herein or otherwise required by the Contract<br />

Documents. The publications of the codes and standards listed below form a part of this<br />

specification section to the same extent as if bound herein.<br />

2. All electrical work shall be in accordance with the latest applicable municipal electrical<br />

code and N.E.C., whichever is more stringent.<br />

3. All work shall be in accordance with the latest applicable municipal building code and<br />

I.B.C., whichever is more stringent.<br />

B. Additional Codes and Standards:<br />

1. Federal Safety and Health Laws: All equipment and accessory items furnished and<br />

installed under this contract shall be governed at all times by applicable provisions of the<br />

Federal laws, including, but not limited to, the latest revisions of the following:<br />

a. William Steiger Occupational Safety and Health Act of 1970, Public Laws 91-596<br />

b. Part 1910 - Occupational Safety and Health Standards, Chapter XVII of Title 29,<br />

Code of Federal Regulations<br />

c. Part 1926 - Occupational Safety and Health Standards, Chapter XVII of Title 29,<br />

Code of Federal Regulations.<br />

d. The Authority’s Construction Safety Manual.<br />

2. Referenced Documents:<br />

a. American Welding Society (AWS)<br />

1) AWS-A2.0 – Standard Welding Symbols<br />

BAGGAGE HANDLING EQUIPMENT 34 77 16 - 2