DCA TERMINAL A IMPROVEMENTS (NEAR TERM) 10 AUGUST 2012<br />

TASK ORDER 03: LOBBY IMPROVEMENTS – PKG 4 - CURBSIDE CHECK-IN<br />

RONALD REAGAN WASHINGTON NATIONAL AIRPORT<br />

PROJECT DT1203<br />

6. Operating Frequency (max): 550MHz<br />

7. Velocity of Propagation: 66% (Nominal)<br />

8. Conductor DC Resistance: 29 Ohms / 1K ft. (Max)<br />

9. Category 6A Horizontal cable shall meet or exceed the following performance<br />

characteristics:<br />

Freq.<br />

MHz<br />

Atten.<br />

dB<br />

Return<br />

Loss<br />

dB<br />

Atten.<br />

/NEXT<br />

Pr. to Pr.<br />

Atten.<br />

/NEXT<br />

PowerSum<br />

NEXT<br />

Pr.to Pr.<br />

NEXT<br />

PowerSum<br />

ELFEXT<br />

Pr.to Pr<br />

ELFEXT<br />

PowerSum<br />

1 1.9 20.1 72.3 70.3 74.3 72.3 67.8 64.8<br />

4 3.7 23.1 61.5 59.5 65.3 63.3 55.7 52.7<br />

8 5.3 24.6 55.4 53.4 60.8 58.8 49.7 46.7<br />

10 5.9 25.1 53.3 51.3 59.3 57.3 47.8 44.8<br />

16 7.5 25.1 48.7 46.7 56.3 54.3 43.7 40.7<br />

20 8.4 25.1 46.3 44.3 54.8 52.8 41.7 38.7<br />

25 9.5 24.4 43.7 41.7 53.3 51.3 39.8 36.8<br />

31.25 10.6 23.7 41.2 39.2 51.9 49.9 37.9 34.9<br />

62.5 15.4 21.6 31.9 29.9 47.4 45.4 31.8 28.8<br />

100 19.8 20.2 24.4 22.4 44.3 42.3 27.8 24.8<br />

155 25.2 18.9 16.1 14.1 41.5 39.5 23.9 20.9<br />

200 29.1 18.1 10.6 8.6 39.8 37.8 21.7 18.7<br />

250 32.9 17.4 5.5 3.3 38.3 36.3 19.8 16.8<br />

300 36.5 19.7 5.4 2.7 37.2 36.1 17.0 15.2<br />

350 37.1 19.6 5.3 2.2 39.4 26.2 16.2 14.8<br />

400 40.2 20.5 5.3 1.1 41.6 25.8 14.7 13.0<br />

550 48 21.3 5.2 -1.0 42.8 22.9 11.9 9.7<br />

C. Special Horizontal cable jacket color code requirements:<br />

1. Horizontal cables utilized for voice service shall have a yellow outer jacket. Horizontal<br />

cables utilized for Data service shall have a blue outer jacket.<br />

2. All horizontal cables shall be plenum rated and bare a CMP marking on the outer jacket.<br />

D. Design Selection: CommScope Systimax X10D 2091x where x = color TBD by MWAA or<br />

approved equal.<br />

2.4 HORIZONTAL STATION CABLES – VIDEO / DATA – SINGLE AND MULTI MODE FIBER<br />

A. All horizontal cables provided for installation shall conform to the requirements of the National<br />

Electric code article 760 and labeled CMP-50 as limited combustion plenum cable.<br />

B. Horizontal fiber optic cables will be extended between the Transportation Security Administration<br />

(TSA) Explosive Detection System (EDS) devices and their serving communications equipment<br />

room. Fiber optic cables provided for installation shall meet or exceed the following minimum<br />

technical requirements:<br />

1. Multi-Mode Fiber Optic Cable:<br />

COMMUNICATIONS HORIZONTAL CABLING 27 15 00 - 5