QF0159 Marketing Release Record
QF0159 Marketing Release Record
QF0159 Marketing Release Record
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Manual Detection Systems<br />
Polymer Detection Systems Polymer Ancillaries<br />
Novolink Polymer Detection Systems<br />
1,250 Tests kit Novolink Max Polymer Detection System<br />
RE7280-K P IVD<br />
500 Tests kit Novolink Polymer Detection System<br />
RE7150-K P IVD<br />
250 Tests kit Novolink Polymer Detection System<br />
RE7140-K P IVD<br />
50 Tests kit Novolink Min Polymer Detection System<br />
RE7290-K P IVD<br />
The Novolink Polymer Detection Systems utilize a novel Compact Polymer<br />
technology. Therefore, the problem of non-specific staining that can occur<br />
with Streptavidin/Biotin detection systems due to endogenous biotin does<br />
not occur. Novolink Polymer Detection Systems contain pre-diluted,<br />
reagents in color coded bottles for ease of use and ultimate convenience.<br />
These systems can be used for the visualization of mouse IgG, mouse IgM<br />
and rabbit IgG primary antibodies. These detection systems contain<br />
Peroxidase Block, Protein Block, Post Primary Block, Novolink Polymer,<br />
DAB Chromogen, Novolink DAB Substrate Buffer (Polymer) and<br />
Hematoxylin.<br />
Novolink Polymer Detection System (RE7150-K) staining for cytokeratin 5 with NCL-L-CK5 on<br />
breast carcinoma. Paraffin section.<br />
/ 114<br />
For detailed information on all products please visit our website:<br />
www.leica-microsystems.com<br />
Peroxidase Block<br />
Blocking Reagent<br />
25 mL RE7101 P<br />
Novocastra Peroxidase Block, RE7101, is intended for use in the peroxidase<br />
based immunohistochemical (IHC) staining procedures. The presence of<br />
pseudoperoxidase (erythrocytes) and endogenous peroxidase in paraffin<br />
sections to be stained by immunoperoxidase procedures, can result in nonspecific<br />
staining. A method for the blocking of pseudoperoxidase was<br />
described (Streefkerk J G, Journal of Histochemistry and Cytochemistry. 20:<br />
829 (1972)). This product is used in a peroxidase based IHC procedure.<br />
Incubating sections with Novocastra Peroxidase Block, RE7101, can<br />
neutralize endogenous peroxidase activity. 25 mL of reagent is supplied.<br />
Protein Block<br />
Blocking Reagent<br />
25 mL RE7102 P<br />
IVD<br />
IVD<br />
Novocastra Protein Block, RE7102, is intended for use in immunohistochemical<br />
(IHC) staining procedures. In immunohistochemistry, diffuse<br />
non-specific staining (background) may occur as a result of hydrophobic<br />
and ionic interactions between antibodies and tissue components.<br />
Novocastra Protein Block, RE7102, is a serum-free, protein blocker. 25 mL of<br />
reagent is supplied.<br />
Novolink Polymer<br />
1,250 Tests kit Novolink Max Polymer RE7260-K P<br />
250 Tests kit Novolink Polymer RE7200-K P IVD<br />
Novolink (Polymer), RE7200-K, is a two part ready-to-use kit comprising<br />
25 mL of Novocastra Post Primary Block, RE7111, and 25 mL of Novolink<br />
Polymer, RE7112, sufficient to perform approximately 250 tests. The larger<br />
format Novolink Max (Polymer), RE7260-K, is a two-part ready-to-use kit<br />
comprising 125 mL of Novocastra Post Primary Block, RE7159, and 125 mL of<br />
Novolink Polymer, RE7161, sufficient to perform approximately 1,250 tests.<br />
Novolink DAB (Polymer)<br />
1,250 Tests kit Novolink Max DAB (Polymer) RE7270-K P<br />
250 Tests kit Novolink DAB (Polymer) RE7230-K P IVD<br />
Novolink Max DAB (Polymer) RE7270-K is a two part DAB kit comprising<br />
150 mL of Novolink Substrate Buffer (Polymer), RE7163, and 8mL of<br />
Novocastra DAB Chromogen, RE7162, sufficient to perform approximately<br />
1,250 tests. Novolink DAB (Polymer), RE7230-K, is a two part DAB kit<br />
comprising 30 mL of Novolink DAB Substrate Buffer, RE7143, and 3 mL of<br />
Novocastra DAB Chromogen, RE7105, sufficient to perform approximately<br />
250 tests.<br />
Products in this catalog are subject to regulatory approval.<br />
Please consult your Leica Microsystems representative for availability in your region.<br />
* For Research Use Only. Not for use in diagnostic procedures.<br />
IVD<br />
IVD