QF0159 Marketing Release Record
QF0159 Marketing Release Record
QF0159 Marketing Release Record
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
BOND<br />
BOND Epitope Retrieval Solution 1<br />
1 L AR9961 P<br />
Components<br />
BOND Epitope Retrieval Solution 1 is a 1 L ready-to-use, citrate based pH 6.0<br />
solution. It is specifically for heat-induced epitope retrieval (HIER) on the<br />
automated BOND system.<br />
Application<br />
BOND Epitope Retrieval Solution 1 is for use on formalin-fixed, paraffinembedded<br />
tissue sections to expose epitopes within tissue that have been<br />
masked during fixation. The solution is gentle on sections as it has a reduced<br />
boiling temperature and utilizes BOND's Covertile technology to prevent<br />
reagent evaporation. Some antibodies, such as BOND ready-to-use Thyroid<br />
Transcription Factor-1, stain optimally when used with BOND Epitope<br />
Retrieval Solution 1. Testing should be carried out to optimize per-formance.<br />
Human lung stained for TTF-1 with BOND ready-to-use Thyroid Transcription Factor-1 (SPT24,<br />
PA0364), using BOND Polymer Refine Detection and BOND Epitope Retrieval Solution 1.<br />
BOND Epitope Retrieval Solution 2<br />
1 L AR9640 P<br />
Components<br />
BOND Epitope Retrieval Solution 2 is a 1 L ready-to-use, EDTA based pH 9.0<br />
solution. It is specifically for heat-induced epitope retrieval (HIER) on the<br />
BOND system.<br />
Application<br />
BOND Epitope Retrieval Solution 2 is for use on formalin-fixed, paraffinembedded<br />
tissue sections to expose epitopes within tissue that have been<br />
masked during fixation. The solution is gentle on sections as it has a<br />
reduced boiling temperature and utilizes BOND's Covertile technology to<br />
prevent reagent evaporation. Some antibodies, such as BOND ready-to-use<br />
CD3 (LN10), stain optimally when used with BOND Epitope Retrieval<br />
Solution 2. Testing should be carried out to optimize performance.<br />
Human tonsil stained for CD3 with BOND ready-to-use CD3 (LN10, PA0533), using BOND<br />
Polymer Refine Detection and BOND Epitope Retrieval Solution 2.<br />
/14<br />
IVD<br />
IVD<br />
For detailed information on all products please visit our website:<br />
www.leica-microsystems.com<br />
Anti-Biotin Antibody<br />
7.5 mL ready-to-use AR0584 P<br />
Components<br />
Anti-Biotin Antibody is a purified anti-biotin, IgG1 isotype. It is supplied<br />
ready-to-use.<br />
Application<br />
In situ hybridization (ISH) allows the detection and visualization of specific<br />
nucleic acids in tissue sections. ISH probes used for detection of DNA on<br />
the BOND contain a biotin label. The Anti-Biotin Antibody allows the linking<br />
of the probe with the detection reagents and consequently visualization of a<br />
chromogenic product by light microscopy.<br />
Anti-Fluorescein Antibody<br />
3.75 mL AR0833 P<br />
15 mL AR0222 P<br />
Components<br />
Anti-Fluorescein Antibody is a purified IgG fraction of a mouse monoclonal<br />
antibody. It is supplied ready-to-use.<br />
Application<br />
In situ hybridization (ISH) allows the detection and visualization of specific<br />
nucleic acids in tissues sections. ISH probes used for the detection of<br />
mRNA on BOND contain a fluorescein label. The Anti-Fluorescein Antibody<br />
allows linking of the oligonucleotide probe with the detection reagents, and<br />
consequently, visualization of a chromogenic product by light microscopy.<br />
BOND Hybridization Solution<br />
100 mL AR9013 RUO*<br />
BOND Hybridization Solution is intended to be used for the dilution of<br />
individual In situ hybridization (ISH) probes for use on the automated Bond<br />
system.<br />
Stringency Wash<br />
6.25 mL AR0633 P<br />
Components<br />
IVD<br />
IVD<br />
IVD<br />
The Stringency Wash Solution is a formamide mixture used with the BOND<br />
DNA Probes. This solution reduces non-specific hybridization of DNA<br />
probes.<br />
Application<br />
In situ hybridization (ISH) allows the detection and visualization of specific<br />
nucleic acids in tissue sections. The Stringency Wash Solution is intended<br />
for use with biotin conjugated DNA probes to reduce non-specific DNA<br />
hybridization in formalin-fixed, paraffin-embedded tissue using the automated<br />
BOND system.<br />
IVD<br />
Products in this catalog are subject to regulatory approval.<br />
Please consult your Leica Microsystems representative for availability in your region.<br />
* For Research Use Only. Not for use in diagnostic procedures.