BOND<br />

BOND Epitope Retrieval Solution 1<br />

1 L AR9961 P<br />

Components<br />

BOND Epitope Retrieval Solution 1 is a 1 L ready-to-use, citrate based pH 6.0<br />

solution. It is specifically for heat-induced epitope retrieval (HIER) on the<br />

automated BOND system.<br />

Application<br />

BOND Epitope Retrieval Solution 1 is for use on formalin-fixed, paraffinembedded<br />

tissue sections to expose epitopes within tissue that have been<br />

masked during fixation. The solution is gentle on sections as it has a reduced<br />

boiling temperature and utilizes BOND's Covertile technology to prevent<br />

reagent evaporation. Some antibodies, such as BOND ready-to-use Thyroid<br />

Transcription Factor-1, stain optimally when used with BOND Epitope<br />

Retrieval Solution 1. Testing should be carried out to optimize per-formance.<br />

Human lung stained for TTF-1 with BOND ready-to-use Thyroid Transcription Factor-1 (SPT24,<br />

PA0364), using BOND Polymer Refine Detection and BOND Epitope Retrieval Solution 1.<br />

BOND Epitope Retrieval Solution 2<br />

1 L AR9640 P<br />

Components<br />

BOND Epitope Retrieval Solution 2 is a 1 L ready-to-use, EDTA based pH 9.0<br />

solution. It is specifically for heat-induced epitope retrieval (HIER) on the<br />

BOND system.<br />

Application<br />

BOND Epitope Retrieval Solution 2 is for use on formalin-fixed, paraffinembedded<br />

tissue sections to expose epitopes within tissue that have been<br />

masked during fixation. The solution is gentle on sections as it has a<br />

reduced boiling temperature and utilizes BOND's Covertile technology to<br />

prevent reagent evaporation. Some antibodies, such as BOND ready-to-use<br />

CD3 (LN10), stain optimally when used with BOND Epitope Retrieval<br />

Solution 2. Testing should be carried out to optimize performance.<br />

Human tonsil stained for CD3 with BOND ready-to-use CD3 (LN10, PA0533), using BOND<br />

Polymer Refine Detection and BOND Epitope Retrieval Solution 2.<br />

/14<br />

IVD<br />

IVD<br />

For detailed information on all products please visit our website:<br />

www.leica-microsystems.com<br />

Anti-Biotin Antibody<br />

7.5 mL ready-to-use AR0584 P<br />

Components<br />

Anti-Biotin Antibody is a purified anti-biotin, IgG1 isotype. It is supplied<br />

ready-to-use.<br />

Application<br />

In situ hybridization (ISH) allows the detection and visualization of specific<br />

nucleic acids in tissue sections. ISH probes used for detection of DNA on<br />

the BOND contain a biotin label. The Anti-Biotin Antibody allows the linking<br />

of the probe with the detection reagents and consequently visualization of a<br />

chromogenic product by light microscopy.<br />

Anti-Fluorescein Antibody<br />

3.75 mL AR0833 P<br />

15 mL AR0222 P<br />

Components<br />

Anti-Fluorescein Antibody is a purified IgG fraction of a mouse monoclonal<br />

antibody. It is supplied ready-to-use.<br />

Application<br />

In situ hybridization (ISH) allows the detection and visualization of specific<br />

nucleic acids in tissues sections. ISH probes used for the detection of<br />

mRNA on BOND contain a fluorescein label. The Anti-Fluorescein Antibody<br />

allows linking of the oligonucleotide probe with the detection reagents, and<br />

consequently, visualization of a chromogenic product by light microscopy.<br />

BOND Hybridization Solution<br />

100 mL AR9013 RUO*<br />

BOND Hybridization Solution is intended to be used for the dilution of<br />

individual In situ hybridization (ISH) probes for use on the automated Bond<br />

system.<br />

Stringency Wash<br />

6.25 mL AR0633 P<br />

Components<br />

IVD<br />

IVD<br />

IVD<br />

The Stringency Wash Solution is a formamide mixture used with the BOND<br />

DNA Probes. This solution reduces non-specific hybridization of DNA<br />

probes.<br />

Application<br />

In situ hybridization (ISH) allows the detection and visualization of specific<br />

nucleic acids in tissue sections. The Stringency Wash Solution is intended<br />

for use with biotin conjugated DNA probes to reduce non-specific DNA<br />

hybridization in formalin-fixed, paraffin-embedded tissue using the automated<br />

BOND system.<br />

IVD<br />

Products in this catalog are subject to regulatory approval.<br />

Please consult your Leica Microsystems representative for availability in your region.<br />

* For Research Use Only. Not for use in diagnostic procedures.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!