PowerVision<br />

PowerVision+ Poly-AP IHC Detection<br />

Systems<br />

1100 tests ready-to-use PV6101 P<br />

Research Use Only<br />

Product Specific Information<br />

PowerVision+ Poly-AP IHC Detection systems are biotin-free, polymeric<br />

alkaline phosphatase (AP) conjugated systems, for the manual detection of<br />

tissue-bound mouse and rabbit antibodies.<br />

Components<br />

These detection systems all contain ready-to-use Post Primary Blocker and<br />

Poly AP Rabbit/Mouse.<br />

Antigen Retrieval Buffer<br />

1000 mL pH 5.5-6.0 (10x concentrate) PV6124 P (HIER) RUO*<br />

1000 mL pH 9.0-9.5 (10x concentrate) PV6125 P (HIER) RUO*<br />

Research Use Only<br />

Antigen Retrieval Buffers are intended for Heat Induced Epitope Retrieval<br />

(HIER) on formalin-fixed, paraffin-embedded tissue sections as part of an<br />

immunohistochemical procedure. HIER using an appropriate pH solution<br />

improves the staining of some antibodies by exposing epitopes within tissue<br />

that has been masked during fixation. A universal HIER technique suitable<br />

for all epitopes does not exist. A combination of different heating methods<br />

and epitope retrieval solutions may be used to optimize unmasking of<br />

antigens where this technique is recommended. HIER is not recommended<br />

for all antibodies. Optimum conditions for epitope retrieval should be<br />

validated by the user, as these are dependant upon tissue, fixation and/or<br />

primary antibody. The 10x solution is supplied in 1000 mL volume, sufficient<br />

to prepare 10 L of working solution.<br />

IHC/ISH Super Blocking<br />

110 mL ready-to-use PV6122 P RUO*<br />

Research Use Only<br />

IHC/ISH Super Blocking is specially formulated to stabilize antibodies and<br />

eliminate background encountered in immunohistochemistry (IHC) and in<br />

situ hybridization (ISH) procedures. The diluent contains complex protein<br />

and non-protein mixtures that eliminate background by blocking nonspecific<br />

protein-protein interactions. It is particularly recommended for<br />

staining of mouse tissues with mouse primary antibodies. It can also be used<br />

as a diluent for primary antibodies. If primary antibodies are diluted in this<br />

solution, a blocking step before primary antibodies can be omitted.<br />

Universal IHC Blocking/Diluent<br />

1000 mL ready-to-use PV6123 P RUO*<br />

Research Use Only<br />

Universal IHC Blocking/Diluent can be used as a blocking reagent prior to<br />

antibody incubation, or as a diluent for antibodies. Pre-blocking should not<br />

be required if antibodies are diluted in this diluent.<br />

/ 144<br />

RUO*<br />

For detailed information on all products please visit our website:<br />

www.leica-microsystems.com<br />

PowerVision DAB Substrate System<br />

60 mL (30 x concentrate) PV6126 P RUO*<br />

Research Use Only<br />

PowerVision DAB Substrate System is a sensitive substrate system for the<br />

visualization of IHC/ISH<br />

Components<br />

This detection system contains two components: 30x concentrated DAB<br />

substrate and 30x concentrated DAB chromogen solution<br />

PowerVision Poly-AP Anti-Mouse IHC<br />

Reagents<br />

1100 tests ready-to-use PV6110 P RUO*<br />

Research Use Only<br />

PowerVision Poly-AP Anti-Mouse IgG is biotin-free, polymeric alkaline<br />

phosphatase (AP) conjugate, for the manual detection of tissue-bound<br />

mouse antibodies.<br />

Components<br />

This system contains ready-to-use Poly AP anti-Mouse IgG.<br />

PowerVision Poly-AP Anti-Rabbit IgG<br />

1100 tests ready-to-use PV6133 P RUO*<br />

Research Use Only<br />

PowerVision Poly-AP Anti-Rabbit IgG is a biotin-free, polymeric alkaline<br />

phosphatase (AP) conjugate, for the manual detection of tissue-bound rabbit<br />

antibodies.<br />

Components<br />

This system contains ready-to-use Poly AP anti-Rabbit IgG.<br />

PowerVision+ Poly-HRP IHC Detection<br />

Systems<br />

1100 tests ready-to-use PV6104 P RUO*<br />

150 tests ready-to-use PV6106 P RUO*<br />

1100 tests ready-to-use PV6107 P RUO*<br />

Research Use Only<br />

PowerVision+ Poly-HRP IHC Detection systems are biotin-free, polymeric<br />

horseradish peroxidase (HRP) conjugated systems, for the manual detection<br />

of tissue-bound mouse and rabbit antibodies.<br />

Components<br />

These detection systems all contain ready-to-use Post Primary Blocker and<br />

Poly HRP anti Rabbit/Mouse. PV6104 also contains a Universal IHC Blocking/<br />

Diluent and two-part DAB Chromogen.<br />

Products in this catalog are subject to regulatory approval.<br />

Please consult your Leica Microsystems representative for availability in your region.<br />

* For Research Use Only. Not for use in diagnostic procedures.