Chapter 2 <strong>Cisco</strong> <strong>Cable</strong> Modem Termination System <strong>Command</strong>s<br />

packetcable gate maxcount<br />

Syntax Description<br />

Defaults 2097152 gate IDs<br />

OL-1581-05<br />

packetcable gate maxcount<br />

To change the maximum number of Packet<strong>Cable</strong> gate IDs in the gate database on the <strong>Cisco</strong> CMTS, use<br />

the packetcable gate maxcount command in global configuration mode. To reset the counter to its<br />

default value, use the no form of this command.<br />

packetcable gate maxcount n<br />

no packetcable gate maxcount<br />

<strong>Command</strong> Modes Global Configuration<br />

<strong>Command</strong> History<br />

n Maximum number of gate IDs to be allocated in the gate database on the<br />

CMTS. The valid range is 512 through 2097152, with a default value of<br />

2097152 (8 * 512 * 512), which is sufficient to support 8 cable interface line<br />

cards.<br />

Release Modification<br />

12.2(8)BC2 This command was introduced for the <strong>Cisco</strong> uBR7200 series universal<br />

broadband router.<br />

12.2(11)BC2 The maximum number of possible gates and the default number of gates<br />

were doubled from 1,048,576 to 2,097,152 to accommodate a maximum of<br />

eight cable interface line cards (where each cable interface line card can use<br />

a maximum of 512*512, or 262,144, gates).<br />

Usage <strong>Guide</strong>lines This command configures the number of gate IDs that the <strong>Cisco</strong> CMTS can store in its gate database.<br />

Because each Packet<strong>Cable</strong> gate ID typically refers to both an upstream gate and a downstream gate,<br />

multiple this number by 2 to get the maximum number of gates that can be created on the CMTS.<br />

Note Each cable interface line card supports a maximum of 512*512 (262,144) Packet<strong>Cable</strong> gates, so ensure<br />

that you set the maximum number of gates to accommodate all installed cable interface line cards.<br />

Examples The following example shows the maximum number of gate IDs being set to 524288, which is sufficient<br />

for two cable interface line cards:<br />

Router# configure terminal<br />

Router(config)# packetcable gate maxcount 524288<br />