Chapter 5 <strong>Cable</strong> CPE <strong>Command</strong>s<br />

OL-1581-05<br />

Voice card specific Info Follows:<br />

Signal Type is loopStart<br />

Ring Frequency is 25 Hz<br />

Hook Status is On Hook<br />

Ring Active Status is inactive<br />

Ring Ground Status is inactive<br />

Tip Ground Status is inactive<br />

Digit Duration Timing is set to 100 ms<br />

InterDigit Duration Timing is set to 100 ms<br />

Router#<br />

Table 5-30 describes the fields shown in this display.<br />

Table 5-30 show voice port Field Descriptions<br />

<strong>Cisco</strong> <strong>Broadband</strong> <strong>Cable</strong> <strong>Command</strong> <strong>Reference</strong> <strong>Guide</strong><br />

show voice port<br />

Field Description<br />

Type of VoicePort Type of voice port: always FXS for the cable access router.<br />

Operations State Operation state of the port.<br />

Administrative State Administrative state of the voice port.<br />

Interface Down Failure Last interface down failure that was reported, if any.<br />

Description Description of the voice port, if any.<br />

Noise Regeneration Whether or not background noise should be played to fill silent<br />

gaps if VAD is activated.<br />

Non Linear Processing Whether or not nonlinear processing is enabled for this port.<br />

Music On Hold Threshold Configured music-on-hold threshold value for this interface.<br />

In Gain Amount of gain inserted at the receiver side of the interface.<br />

Out Attenuation Amount of attenuation inserted at the transmit side of the interface.<br />

Echo Cancellation Whether or not echo cancellation is enabled for this port.<br />

Echo Cancel Coverage Echo cancel coverage for this port.<br />

Connection Mode Connection mode of the interface.<br />

Connection Number Full E.164 telephone number used to establish a connection with<br />

the trunk or PLAR mode.<br />

Initial Time Out Amount of time the system waits for an initial input digit from the<br />

caller.<br />

Interdigit Time Out Amount of time the system waits for a subsequent input digit from<br />

the caller.<br />

Call-Disconnect Time Out Number of seconds for an idle call to be disconnected.<br />

Ringing Time Out Ringing time out duration.<br />

Region Tone Configured regional tone for this interface.<br />

Currently Processing Type of call currently being processed: none, voice, or fax.<br />

Maintenance Mode Maintenance mode of the voice port.<br />

Number of signaling protocol<br />

errors<br />

Number of signalling protocol errors.<br />

Impedance Configured terminating impedance for the E&M interface.<br />

5-163