Chapter 2 <strong>Cisco</strong> <strong>Cable</strong> Modem Termination System <strong>Command</strong>s<br />

show interface cable monitor<br />

Syntax Description<br />

<strong>Command</strong> Modes Privileged EXEC<br />

<strong>Command</strong> History<br />

OL-1581-05<br />

show interface cable monitor<br />

To display cable monitor information, use the show interface cable monitor command in privileged<br />

EXEC mode.<br />

show interface cable {slot/port | slot/subslot/port} monitor<br />

slot/port Identifies the cable interface and downstream port on the <strong>Cisco</strong> uBR7100 series<br />

and <strong>Cisco</strong> uBR7200 series routers.<br />

On the <strong>Cisco</strong> uBR7100 series router, the only valid value is 1/0. On the<br />

<strong>Cisco</strong> uBR7200 series router, slot can range from 3 to 6, and port can be 0 or 1,<br />

depending on the cable interface.<br />

slot/subslot/port Identifies the cable interface on the <strong>Cisco</strong> uBR10012 router. The following are<br />

the valid values:<br />

slot = 5 to 8<br />

subslot = 0 or 1<br />

Examples The following is sample output from the show interface cable monitor command:<br />

CMTS01# show interface cable 5/0 monitor<br />

port = 0 to 4 (depending on the cable interface)<br />

Release Modification<br />

12.1(3a)EC This command was introduced.<br />

12.2(4)XF Support was added for the <strong>Cisco</strong> uBR10012 universal broadband router.<br />

12.2(4)BC1 Support was added to the Release 12.2 BC train.<br />

US/ Time Outbound Flow Flow Type Flow Packet MAC MAC Encap<br />

DS Stmp Interface Type Identifier Extn. Type Extn. Type Type<br />

us no Et1/2 us-port 0 yes data no - docsis<br />

all no Et1/2 acc-list 103 yes data no - docsis<br />

all yes Et1/2 mac-addr 0050.0000.0000 yes mac no - -<br />

Table 2-38 show interface cable monitor Field Descriptions<br />

Field Description<br />

DS Downstream. Indicates that only downstream flows are monitored.<br />

UP Upstream. Indicates that only upstream flows are monitored.<br />

ALL Indicates that all flows are monitored.<br />