C200HW-SRM21-V1 Master Unit for CS-series, C200HX/C200HG/C200HE-(Z)E, and C200HS PLCsSection 4-1<br />

C200HX-<br />

CPU5@/-<br />

CPU6@/-<br />

CPU8@-(Z)E,<br />

C200HG-<br />

CPU5@/-<br />

CPU6@-(Z)E<br />

First word<br />

CIO 2000<br />

CIO 2010<br />

CIO 2020<br />

CIO 2030<br />

CIO 2040<br />

CIO 2050<br />

CIO 2060<br />

CIO 2070<br />

CIO 2080<br />

CIO 2090<br />

CIO 2100<br />

CIO 2110<br />

CIO 2120<br />

CIO 2130<br />

CIO 2140<br />

CIO 2150<br />

First word<br />

IR 100<br />

IR 110<br />

IR 120<br />

IR 130<br />

IR 140<br />

IR 150<br />

IR 160<br />

IR 170<br />

IR 180<br />

IR 190<br />

IR 400<br />

IR 410<br />

IR 420<br />

IR 430<br />

IR 440<br />

IR 450<br />

Unit number 0<br />

Unit number 1<br />

Unit number 2<br />

Unit number 3<br />

Unit number 4<br />

Unit number 5<br />

Unit number 6<br />

Unit number 7<br />

Unit number 8<br />

Unit number 9<br />

Unit number A<br />

Unit number B<br />

Unit number C<br />

Unit number D<br />

Unit number E<br />

Unit number F<br />

Unit number 0<br />

Unit number 1<br />

Unit number 2<br />

Unit number 3<br />

Unit number 4<br />

Unit number 5<br />

Unit number 6<br />

Unit number 7<br />

Unit number 8<br />

Unit number 9<br />

Unit number A<br />

Unit number B<br />

Unit number C<br />

Unit number D<br />

Unit number E<br />

Unit number F<br />

CS-series PLCs<br />

15<br />

First word<br />

First word + 1<br />

First word + 2<br />

First word + 3<br />

First word + 4<br />

First word + 5<br />

First word + 6<br />

First word + 7<br />

First word + 8<br />

First word + 9<br />

Slave allocations in Special I/O Unit Area<br />

14 13 12 11 10<br />

Output Slave 1<br />

Output Slave 3<br />

Output Slave 5<br />

Output Slave 7<br />

Input Slave 1<br />

Input Slave 3<br />

Input Slave 5<br />

Input Slave 7<br />

C200HX/C200HG/C200HE-(Z)E, and C200HS PLCs<br />

I/O Allocations when Pin 1 is ON<br />

9<br />

8<br />

7 6 5 4 3 021<br />

Output Slave 0<br />

Output Slave 2<br />

Output Slave 4<br />

Output Slave 6<br />

Input Slave 0<br />

Input Slave 2<br />

Input Slave 4<br />

Input Slave 6<br />

Active Output Slave Flags<br />

Active Input Slave Flags<br />

Output Slave Error Flags<br />

#7 #0 #7 #0<br />

Input Slave Error Flags<br />

#7 #0 #7 #0<br />

First w ord<br />

First word + 1<br />

First word + 2<br />

First word + 3<br />

First word + 4<br />

First word + 5<br />

First word + 6<br />

First word + 7<br />

Slave allocations in Special I/O Unit Area<br />

Output Slave 1<br />

Output Slave 3<br />

Output Slave 5<br />

Output Slave 7<br />

Input Slave 1<br />

Input Slave 3<br />

Input Slave 5<br />

Input Slave 7<br />

Output Slave Error Flags<br />

Input Slave Error Flags<br />

When pin 1 is ON and node addresses IN0 to IN15 and OUT0 to OUT15 (128<br />

inputs/128 outputs max) are used, words are allocated to the Slaves for each<br />

node number as shown in the following diagrams.<br />

Bits<br />

Outputs<br />

Inputs<br />

Status<br />

Bits<br />

Output Slave 0<br />

Output Slave 2<br />

Outputs<br />

Output Slave 4<br />

Output Slave 6<br />

Input Slave 0<br />

Input Slave 2<br />

Input Slave 4<br />

Inputs<br />

Input Slave 6<br />

Active Output Slave Flags<br />

Status<br />

Active Input Slave Flags<br />

First word + 8<br />

#7 #0 #7 #0<br />

First word + 9<br />

#7 #0 #7 #0<br />

79