CPM2C-S Series CPM2C-S@@@C (-DRT) Section 4-6<br />

Timer/Counters 256 bits: TIM/CNT 000 to 255<br />

1-ms timer (TMHH instruction), 10-ms timer (TIMH instruction), 100-ms timer<br />

(TIM instruction), 1-s/10-s timer (TIML instruction), Decrementing counter<br />

(CNT instruction), and reversible counter (CNTR instruction)<br />

DM words Read/Write: 2,048 words (DM 0000 to 2047) (DM 2000 to 2021 are the error<br />

log area.)<br />

Read-only: 456 words (DM 6144 to 6599)<br />

PLC Setup: 56 words (DM 6600 to 6655)<br />

<strong>CompoBus</strong>/S Master<br />

function<br />

Dimensions (Same for All Units)<br />

142<br />

Item Specification<br />

I/O points 256 points (128 inputs and 128 outputs) or 128 points (64 inputs and 64 outputs)<br />

(Determined by the node number settings in the DM Area. The value is by<br />

default set to 256.)<br />

Number of points 8-point mode<br />

per node number<br />

Node number setting<br />

IN0 to IN15 and OUT0 to OUT15 or IN0 to IN7 and OUT0 to OUT7 (selected<br />

with DM settings)<br />

I/O words Input: 020 to 027 (<strong>CompoBus</strong>/S input bits)<br />

Output: 030 to 037 (<strong>CompoBus</strong>/S output bits)<br />

DeviceNet Slave function DeviceNet remote I/O link points: Up to 1,024 points (Up to 32 input words<br />

and 32 output words)<br />

Explicit message communications<br />

Read/Write any desired area from the Master<br />

Power failure backup function Flash memory: User program, DM (Read only), and PLC Setup<br />

Memory backup: Holds DM (Read/Write), HR, AR, and CNT contents with<br />

battery for 2 years at an ambient temperature of 25°C.<br />

Programming Device CQM1H-PRO01-E, CQM1-PRO01-E, or C200H-PRO27-E Programming<br />

Console<br />

WS02-CXPC1-EV2 CX-Programmer<br />

WS01-CPTB1-E SYSMAC-CPT<br />

C500-ZL3AT1-E SYSMAC Support Software<br />

(Unit: mm)<br />

The CPM2C-S has rotary switches for DeviceNet settings and communications<br />

connector only if the CPM2C-S model number has a suffix of “DRT.” For<br />

the dimensions of the CPM2C-S with wires connected or Expansion Units<br />

mounted, refer to the CPM2C-S Series Operation Manual.