03.08.2013 Views

OPERATION MANUAL CompoBus/S

OPERATION MANUAL CompoBus/S

OPERATION MANUAL CompoBus/S

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Operations Checklist Section 3-5<br />

CS-series Master<br />

Units<br />

CJ-series Master<br />

Units<br />

CQM1 Master<br />

Units<br />

Item Check Answer<br />

Switch settings Has the Master’s Special I/O Unit number been set?<br />

(Refer to 4-2-2 Switch Settings for details.)<br />

Has the node number been set with pin 1 of the DIP switch?<br />

(Refer to 4-2-2 Switch Settings for details.)<br />

Has the communications mode been set with pin 2 of the DIP switch?<br />

(Refer to 4-2-2 Switch Settings for details.)<br />

Has the communications stop mode been set with pin 3 of the DIP<br />

switch?<br />

(Refer to 4-2-2 Switch Settings for details.)<br />

Has the Slave registration function been set with pin 4 of the DIP<br />

switch? (If the Slave registration function is used, the CPU Unit’s DM<br />

Area must also be set.)<br />

(Refer to 4-2-2 Switch Settings for details.)<br />

Switch settings Has the Master’s Special I/O Unit number been set?<br />

(Refer to 4-3-2 Switch Settings for details.)<br />

Has the node number been set with pin 1 of the DIP switch?<br />

(Refer to 4-3-2 Switch Settings for details.)<br />

Has the communications mode been set with pin 2 of the DIP switch?<br />

(Refer to 4-3-2 Switch Settings for details.)<br />

Has the communications stop mode been set with pin 3 of the DIP<br />

switch?<br />

(Refer to 4-3-2 Switch Settings for details.)<br />

Has the Slave registration function been set with pin 4 of the DIP<br />

switch? (If the Slave registration function is used, the CPU Unit’s DM<br />

Area must also be set.)<br />

(Refer to 4-3-2 Switch Settings for details.)<br />

Yes No<br />

Yes No<br />

Yes No<br />

Yes No<br />

Yes No<br />

Yes No<br />

Yes No<br />

Yes No<br />

Yes No<br />

Yes No<br />

Switch settings Has the PLC word allocation (DIP switch pins 1 and 2) been set?<br />

(Refer to 4-4-2 Switch Settings for details.)<br />

Yes No<br />

Has the number of points/node number setting (DIP switch pin 3)<br />

been set? (Refer to 4-4-2 Switch Settings for details.)<br />

Yes No<br />

Has the communications mode been set with pin 4 of the DIP switch?<br />

(Refer to 4-4-2 Switch Settings for details.)<br />

Yes No<br />

Are pins 5 and 6 of the DIP switch all set to OFF? Yes No<br />

Slaves Switch settings Has the node number been set?<br />

(Refer to SECTION 5 Slave Specifications and Operations for<br />

details.)<br />

Has the communications mode been set?<br />

(Refer to SECTION 5 Slave Specifications and Operations for<br />

details.)<br />

Yes No<br />

Yes No<br />

Is the Slave’s node number unique (not allocated to another Slave)? Yes No<br />

Have other settings besides the <strong>CompoBus</strong>/S settings, such as the<br />

“hold/clear outputs for communications error” setting, been set?<br />

(Refer to SECTION 5 Slave Specifications and Operations for<br />

details.)<br />

Yes No<br />

71

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!