C200HW-SRM21-V1 Master Unit for CS-series, C200HX/C200HG/C200HE-(Z)E, and C200HS PLCsSection 4-1<br />

Data area Bit(s) Name Function<br />

AR Area AR 0000 to<br />

AR 0009<br />

DM Area<br />

(PLC<br />

Setup)<br />

C200HS PLCs<br />

AR 0100 to<br />

AR 0109<br />

DM 6620 (bits<br />

00 to 09)<br />

DM 6623 (bits<br />

00 to 15)<br />

Special I/O Unit Error Flags These flags are turned ON when there is an error in data<br />

transfers between the PLC and the corresponding Special<br />

I/O Unit or the same unit number has been set on more<br />

than one Special I/O Unit. Each bit corresponds to the Unit<br />

with the same unit number.<br />

(Bits SR 28200 to SR 28209 show the same information for<br />

Special I/O Units 0 to 9.)<br />

Special I/O Unit Restart Bits Turn the corresponding bit OFF→ON→OFF to restart a<br />

Special I/O Unit. Each bit corresponds to the Unit with the<br />

same unit number.<br />

(Bits SR 28100 to SR 28109 can also be used to restart<br />

Special I/O Units 0 to 9.)<br />

Special I/O Unit Refresh Disable<br />

Bits<br />

Special I/O Unit Refresh Disable<br />

Bits<br />

Turn the corresponding bit ON to disable refreshing of the<br />

corresponding Special I/O Unit (except Remote I/O Racks).<br />

Each bit corresponds to the Unit with the same unit number.<br />

(Bits 00 to 09 of DM 6623 can also be used to disable<br />

refreshing of Special I/O Units 0 to 9.)<br />

Turn the corresponding bit ON to disable refreshing of the<br />

corresponding Special I/O Unit (except Remote I/O Racks).<br />

Each bit corresponds to the Unit with the same unit number.<br />

(Bits 00 to 09 of DM 6620 can also be used to disable<br />

refreshing of Special I/O Units 0 to 9.)<br />

Data area Bit(s) Name Function<br />

SR Area SR 25415 Special I/O Unit Error Flag This flag is turned ON when there is an error in data transfers<br />

between the PLC and a Special I/O Unit or the same<br />

unit number has been set on more than one Special I/O<br />

Unit.<br />

The unit number of the affected Unit is written to AR 00.<br />

SR 27400 to<br />

SR 27409<br />

AR Area AR 0000 to<br />

AR 0009<br />

DM Area<br />

(PLC<br />

Setup)<br />

AR 0100 to<br />

AR 0109<br />

DM 6620<br />

(bits 00 to 09)<br />

Special I/O Unit Restarting<br />

Flags<br />

These flags are turned ON while a Special I/O Unit is<br />

restarting. Each bit corresponds to the Unit with the same<br />

unit number.<br />

Special I/O Unit Error Flags These flags are turned ON when there is an error in data<br />

transfers between the PLC and the corresponding Special<br />

I/O Unit or the same unit number has been set on more<br />

than one Special I/O Unit. Each bit corresponds to the Unit<br />

with the same unit number.<br />

Special I/O Unit Restart Bits Turn the corresponding bit OFF→ON→OFF to restart a<br />

Special I/O Unit. Each bit corresponds to the Unit with the<br />

same unit number.<br />

Special I/O Unit Refresh Disable<br />

Bits<br />

Turn the corresponding bit ON to disable refreshing of the<br />

corresponding Special I/O Unit (except Remote I/O Racks).<br />

Each bit corresponds to the Unit with the same unit number.<br />

87