Fiber Amplifier Communications Units Section 5-6<br />

Slave Part Names and Functions<br />

Item Specification<br />

Connection Inputs:<br />

Fiber Amplifier Units<br />

Communications:<br />

Communications Connector (standard connector provided<br />

with Unit)<br />

I/O power:<br />

Communications Connector (standard connector provided<br />

with Unit)<br />

Power supply type Network power supply<br />

Communications power<br />

supply voltage<br />

I/O power supply voltage<br />

Current consumption<br />

(See note.)<br />

Maximum input delay<br />

time<br />

14 to 26.4 V DC<br />

(Power can be supplied from the communications cable)<br />

Communications power: 30 mA max. at 24 V DC<br />

Up to 8 Sensors connected:<br />

0.1 × n + 1.5 (ms) (n: unit number)<br />

9 or more Sensors connected:<br />

0.2 × n + 1.5 (ms) (n: unit number)<br />

Ambient temperature Operating: –20 to 55°C (with no icing or condensation)<br />

Storage: –30 to 70°C (with no icing or condensation)<br />

Ambient humidity Operating: 35% to 85% (with no condensation)<br />

Operating environment No corrosive gases<br />

Node number settings The node number is set on a rotary switch. (Set the node<br />

number before turning ON the Slave.)<br />

Dimensions 30 × 34.6 × 71.3 mm (W × H × D)<br />

Weight 150 g max.<br />

Note This is the current consumption when all the maximum simultaneous input<br />

points are ON, excluding the current consumption of external sensors.<br />

E3X-MC11 Mobile<br />

Console Connector<br />

Used to connect the<br />

Mobile Console.<br />

DIP switch<br />

Communications Connector<br />

Communications connector for<br />

<strong>CompoBus</strong>/S used to supply power<br />

from the <strong>CompoBus</strong>/S communications<br />

power terminal to all the Sensors<br />

connected to the Communications Unit<br />

ON<br />

1 234<br />

NODE<br />

ADR<br />

0 2 4 6 8 A C E<br />

1 3 5 7 9 11 13 15<br />

PWR<br />

COMM<br />

ERR<br />

U.ERR<br />

SS<br />

Rotary switches<br />

Sensor reset switch<br />

Resets the connected sensor by<br />

turning the power supply OFF and ON.<br />

LED indicators<br />

Power supply connectors<br />

The E3X-SRT21 is supplied<br />

power from the<br />

communications connector, so<br />

power supply cables are not<br />

used.<br />